VFD Shielded Tray Cable

Variable Frequency Drive Cable (VFD Cable)

VFD Shielded Tray Cable
RoHS Hook-up WireRoHS Compliant

VFD Shielded Tray Cable Approvals:

  • CE
  • Type WTTC 90°C 1000V
  • UL MTW 4 AWG/4C 600V
  • Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4
  • AWM Style 21179 105°C 1000V
  • c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4
  • CSA AWM I/II A/B 90°C 1000V FT1 FT2

VFD Shielded Tray Cable Construction:

  • Conductor: Tinned copper strands
  • Insulation: Special Formulated PVC/Nylon
  • Color Code: Black conductors with consecutive white numbers and green-yellow earth wire.
  • Stranding: In layers.
  • Wrapping: Non-woven tape
  • Screen: Double shield, alu foil and tinned copper braiding
  • Jacket Material: Special sunlight and oil resistant PVC
  • Jacket Color: Black

VFD Shielded Tray Cable Applications:

  • VFD Shielded Tray Cable is designed for automated servo systems, and is suitable for tray cable application and also as Control and Instrumentation Cable. The VFD can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50' of open wiring to make installations less cumbersome. This shielded tray cable has an outer PVC jacket and both a foil and a braid shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. VFD Shielded Tray Cable can be used without jacket (exposed runs) and is permitted to be used in hazardous (classified) locations class I, Division 2.

VFD Shielded Tray Cable Technical Data:

  • VFD Shielded Tray Cable Nominal Voltage:
    • (UL)/c(UL): 600V
    • UL-AWM/CSA-AWM: 1000 v
  • VFD Shielded Tray Cable Testing Voltage:
    • Conductor/Conductor: 7500 V
    • Conductor/Screen: 3000 V
  • VFD Shielded Tray Cable Minimum Bending Radius: 7.5 x O.D.
  • VFD Shielded Tray Cable Temperature Range:
    • UL-AWM: up to +105°C
    • (UL)/c(UL)/CSA-AWM: up to +90°C
  • Burning Characteristics: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2
  • Oil Resistant: Yes
  • Sunlight Resistance: Yes
  • Exposed Runs: Yes
  • Direct Burial: Yes

 

Part Number AWG SizeNo. of Cond.Conductor StrandingApprox LBS/MFTNom. O.D. of Cable (in)Nom. Dia. of Cond.
4305902-54 18 4 30/32 75 0.354 0.097
4305802-54 16 4 29/30 91 0.382 0.108
4305702-54 14 4 46/30 120 0.417 0.124
4305602-54 12 4 75/30 177 0.472 0.147
4305502-54 10 4 113/30 278 0.602 0.186
4305402-54 8 4 180/30 430 0.764 0.250
4305302-54 6 4 287/30 633 0.941 0.309
4305202-54 4 4 448/30 916 1.118 0.380
4305102-54 2 4 691/30 1283 1.287 0.449