XLPE/PVC Unshielded Control Cable

XLPE/PVC Control and Power Cable

XLPE/PVC Unshielded Control Cable
UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC, 600V

Product Approvals:

  • Industry Approvals
    • UL 44 Type XHHW-2
    • UL 1277 Type TC-ER for 3 or more conductors
    • UL 1581
    • ICEA S-73-532
    • ICEA S-95-658/NEMA WC70
  • Flame Tests Approvals
    • UL 1581 VW-1
    • UL 1277
    • IEEE 383
    • IEEE 1202
    • CSA FT4
  • Other Compliances:
    • Meeets EPA 10 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

XLPE/PVC Unshielded Control Cable Construction:

  • Conductor:
    • 14 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3
    • Class B stranding per ASTM B8
  • Insulation:
    • Flame Retardant Cross-Linked Polyethylene (XLPE)
    • Color-coded per ICEA Method 1; Table E-2 Does not include white or green
  • Jacket:
    • Flame retardant and sunlight resistant Polyvinyl Chloride (PVC)

XLPE/PVC Unshielded Control Cable Options:

  • Tinned copper conductor
  • Class C stranding
  • E-1 Color Code
  • Overall shielded multi conductors
  • Ethylene Propylene Rubber (EPR) insulation
  • Low-lead Hypalon Chlorosulfonated Polyethylene (CSPE) / Elastomer blend
  • Insulated or uninsulated ground conductor
  • Other constructions available upon request

XLPE/PVC Unshielded Control Cable Applications:

  • In free air, raceways and direct burial
  • In wet or dry locations
  • Approved for direct burial, Class I, Div 2 industrial hazardous locations per NEC
  • Permitted for Exposed Run 'ER' use in accordance with NEC for 3 or more conductors

XLPE/PVC Unshielded Control Cable Features:

  • Rated at 90°C wet or dry
  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Excellent electrical properties
  • Abrasion and chemical resistant
  • Sunlight and weather resistant
  • Meets ICEA and CSA cold bend test at -25°C
  • Meets the crush and impact requirements of Type MC
Part Number AWG SizeNo. of Cond.Conductor StrandingNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Jacket ThickApprox DimensionGround AWG Size
385230-18 14 2 7/.0242 62 .030 .045 .235 x .370
385540-18 14 2 7/.0242 0.3650 73 .030 .045
385265-18 14 3 7/.0242 0.3900 93 .030 .045
385305-18 14 4 7/.0242 0.4250 116 .030 .045
385210-18 14 5 7/.0242 0.4650 140 .030 .045
385280-18 14 7 7/.0242 0.5900 176 .030 .045
385270-18 14 9 7/.0242 0.6200 245 .030 .060
385235-18 14 12 7/.0242 0.6800 302 .030 .060
385275-18 14 19 7/.0242 0.8000 460 .030 .060
385225-18 14 25 7/.0242 0.9850 641 .030 .080
147660-18 14 30 7/.0242 1.0500 740 .030 .080
385215-18 14 37 7/.0242 1.1300 888 .030 .080
385240-18 12 2 7/.0305 86 .030 .045 .245 x 400
173460-18 12 2 7/.0305 0.4100 96 .030 .045
182860-18 12 3 7/.0305 0.4350 143 .030 .045 12
385285-18 12 3 7/.0305 0.1350 125 .030 .045
385245-18 12 4 7/.0305 0.4750 157 .030 .045
385205-18 12 5 7/.0305 0.5150 191 .030 .045
385475-18 12 7 7/.0305 0.5950 260 .030 .060
385290-18 12 9 7/.0305 0.6950 340 .030 .060
385260-18 12 12 7/.0305 0.7800 429 .030 .060
385350-18 12 19 7/.0305 0.9300 681 .030 .080
173555-18 12 25 7/.0305 1.0950 885 .030 .080
173560-18 12 30 7/.0305 1.1500 1005 .030 .080
173565-18 12 37 7/.0305 1.2400 1185 .030 .080
385295-18 10 2 7/.0385 114 .030 .045 .290 x .480
173465-18 10 2 7/.0385 0.4550 130 .030 .045
385335-18 10 3 7/.0385 0.4850 201 .030 .045 10
385300-18 10 3 7/.0385 0.4850 173 .030 .045
385185-18 10 4 7/.0385 0.5150 236 .030 .060
385190-18 10 5 7/.0385 0.6150 287 .030 .060
385450-18 10 7 7/.0385 0.6700 371 .030 .060
385195-18 10 9 7/.0385 0.7850 479 .030 .060
385200-18 10 12 7/.0385 0.8950 644 .030 .080