XLPE/PVC Unshielded Low-Voltage Power Cable

XLPE/PVC Control and Power Cable

XLPE/PVC Unshielded Low-Voltage Power Cable
UL Type TC-ER
600V

Product Approvals:

  • Industry Approvals
    • UL 44 Type XHHW-2
    • UL 1277 Type TC-ER
    • UL 1581
    • ICEA S-95-658/NEMA WC70
  • Flame Tests Approvals
    • UL 1581 VW-1
    • UL 1277
    • IEEE 383
    • IEEE 1202
    • CSA FT4
  • Other Compliances:
    • Meeets EPA 10 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

XLPE/PVC Unshielded Low-Voltage Power Cable Construction:

  • Conductor:
    • 14 AWG thru 750 kcmil bare, annealed copper per ASTM B3
    • Class B stranding per ASTM B8
  • Insulation:
    • Flame Retardant Cross-Linked Polyethylene (XLPE)
    • Color-coded per ICEA Method 4; Individual conductors colored black with conductor number surface printed in contrasting ink
  • Ground:
    • Uninsulated bare annealed copper per ASTM B3
    • Class B stranding per ASTM B8
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)

XLPE/PVC Unshielded Low-Voltage Power Cable Options:

  • Tinned copper conductor
  • Class C stranding
  • E-1 or E-2 Color Code
  • Insulated ground conductors
  • Overall shielded multi conductors
  • Flame Retardant Ethylene Propylene Rubber (EPR) insulation
  • Low-lead Hypalon Chlorosulfonated Polyethylene (CSPE) / Elastomer blend
  • ICEA 1000V rated cable
  • Other constructions available upon request

XLPE/PVC Unshielded Low-Voltage Power Cable Applications:

  • In free air, raceways and direct burial
  • In wet or dry locations
  • Permitted for use in Class I, Div 2 industrial hazardous locations per NEC
  • Permitted for Exposed Run 'ER' use in accordance with NEC

XLPE/PVC Unshielded Low-Voltage Power Cable Features:

  • Rated at 90°C wet or dry
  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Excellent electrical properties
  • Abrasion and chemical resistant
  • Sunlight and weather resistant
  • Meets cold bend test at -25°C
  • Meets the crush and impact requirements of Type MC

 

Part Number No. of Cond.Conductor StrandingNom. O.D. (in)Approx LBS/MFTAWG SizeNom. Insul. Thick. (in)Jacket ThickGround AWG Size
191930-18 3 7/.0242 0.4250 116 14 .030 .045 14
191935-18 3 7/.0305 0.4750 157 12 .030 .045 12
191940-18 3 7/.0385 0.5150 236 10 .030 .060 10
391580-18 3 7/.0486 0.6400 314 8 .045 .060 10
391595-18 4 7/.0486 0.7050 385 8 .045 .060 10
169735-18 3 7/.0612 0.7200 445 6 .045 .060 8
169740-18 4 7/.0612 0.7900 558 6 .045 .060 8
391665-18 3 7/.0772 0.8750 653 4 .045 .080 8
169750-18 4 7/.0772 0.9500 820 4 .045 .080 8
162805-18 3 7/.0974 1.0000 964 2 .045 .080 6
164760-18 4 7/.0974 1.0950 1214 2 .045 .080 6
176075-18 3 19/.0664 1.1200 1199 1 .055 .080 6
185625-18 4 19/.0664 1.2350 1704 1 .055 .080 6
169765-18 3 19/.0745 1.2150 1414 1/0 .055 .080 6
169770-18 4 19/.0745 1.3400 1825 1/0 .055 .080 6
169775-18 3 19/.0837 1.3100 1706 2/0 .055 .080 6
169780-18 4 19/.0837 1.4500 2223 2/0 .055 .080 6
185630-18 3 19/.0940 1.4200 2437 3/0 .055 .080 4
185635-18 4 19/.0940 1.5700 3123 3/0 .055 .080 4
391615-18 3 19/.1055 1.5400 2600 4/0 .055 .080 4
169785-18 4 19/.1055 1.7650 3444 4/0 .055 .110 4
164270-18 3 37/.0822 1.7500 3142 250 .065 .110 4
169795-18 4 37/.0822 1.9300 4048 250 .065 .110 4
111285-18 3 37/.0973 1.9700 4230 350 .065 .110 3
169800-18 4 37/.0973 2.1800 5470 350 .065 .110 3
111355-18 3 37/.1162 2.2500 5829 500 .065 .110 2
3395.043250-18 4 37/.1162 2.4500 7579 500 .065 .110 2
3395.038500-18 3 61/.1109 2.8100 9101 750 .080 .140 1
3395.023500-18 4 61/.1109 3.115 11746 750 .080 .140 1