Belden VFD Cable

Belden Industrial Cable, Control and Automation Cable

VFD Cables, Variable Frequency Drive Cable
1000V UL Flexible Motor Supply Cable
Exposed Run Tray Cable, TC-ER Cable
Belden VFD

VFD Cable Ratings and Approvals:

  • UL 1277 (600V)
  • Type TC-ER (Tray Cable – Exposed Run) per 2005 NEC Article 336
  • CSA AWM I/II A/B FT4 (1000V)
  • 90°C Wet or Dry
  • XHHW-2 Rated Circuit Conductors (and RHW-2 for 4-cond. Parts)

VFD Cable Construction:

  • 4 Conductor Parts:
    • Conductors: 3 Stranded Tinned Copper Circuit Conductors and 1 Ground
    • Insulation: XLPE (Circuit Conductors) and PVC (Ground)
    • Shielding: Overall Beldfoil (100% Coverage) and Tinned Copper Braid (85% Coverage)
    • Jacket: Black Sunlight and Oil-Resistant PVC
    • Color Code: ICEA Method 4: Black and Numbered, Green/Yellow Ground
  • 6 Conductor Parts:
    • Conductors: 3 Stranded Tinned Copper Circuit Conductors and 3 Symmetrical Bare Copper Grounds
    • Insulation: XLPE (Circuit Conductors)
    • Shielding: 2 Spiral Copper Tape Shields (100% Coverage)
    • Jacket: Black Sunlight and Oil-Resistant PVC
    • Color Code: ICEA Method 4: Black and Numbered
Part Number AWG SizeNo. of Cond.Conductor StrandingComposite ConstructionNom. O.D. (in)Approx LBS/MFT
29500 16 4 26/30 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 0.5300 182
29501 14 4 41/30 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 0.5500 233
29502 12 4 65/30 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 0.6000 298
29503 10 4 105/30 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 0.6600 375
29504 8 4 7/19/29 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 0.8900 660
29505 6 4 7/19/27 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 0.9900 906
29506 4 4 7/19/25 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 1.1500 1231
29507 2 4 7/19/23 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (1) Ground with PVC Insulation 1.2900 1711
29528 1 3 7/19/22 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (3) Symmetrical Bare Copper Grounds 1.2000 1642
29529 1/0 3 7/19/21 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (3) Symmetrical Bare Copper Grounds 1.2900 2050
29530 2/0 3 7/19/20 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (3) Symmetrical Bare Copper Grounds 1.4000 2362
29531 3/0 3 7/19/19 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (3) Symmetrical Bare Copper Grounds 1.5200 2708
29532 4/0 3 7/19/18 (3) Stranded Tinned Copper Circuit Conductors with XLPE Insulation, (3) Symmetrical Bare Copper Grounds 1.6800 3746