General Cable MOR® Polyrad® IEEE 1580 Type P Unarmored Flexible Variable Frequency Drive Power Cable

General Cable MOR® Polyrad® IEEE 1580 Type P Cable
Unarmored Flexible Variable Frequency Drive Power Cable
2 kV/1000 V

General Type P Cable Construction:

  • Conductor: 8 AWG thru 777 kcmil soft annealed flexible stranded Tinned Copper
  • Insulation: Polyrad® XT-125 Irradiated Cross-Linked Polyolefin (XLPO)
  • Color Code: All black with printed numbers
  • Ground: 3 split green covered flexible Tinned Copper conductors sized to UL 1277
  • Jacket: Thermoset Cross-Linked Chlorinated Polyethylene (XL-CPE) (14446.037000IG only)
  • Shield: Overall Tinned Copper braid with Aluminum/Polyester tape - 100% coverage for enhanced shield effectiveness required by VFD applications
  • Sheath: Mud oil-resistant, black Irradiated Cross-Linked Chlorosulfonated Polyethylene (PE)
  • Print (including but not limited to): MOR® POLYRAD® XT-125 VFD (UL) E85994 BR782 110C 3C XXAWG+3GRNDS SHIELDED TC-ER RHW -- (CSA) LL 9755 SPEC 245/1309 FT4 -40C SR 600 V RW90 SR XLPE TC (ETL) US 109229 IEEE 1580-2001 -- IEC 1 KV 60332.3A DAY/MONTH/YEAR SEQUENTIAL MARK
  • Options:
    • Overall braid wire armor
    • Larger sized covered ground wires
    • Covered ground wires

General Type P Cable Applications:

  • General Cable IEEE 1580 Type P cable is designed for use in AC motor variable frequency drives, offshore oil and gas drilling platforms, MODUS, ships and FPSOs. These cables are approved for use in Class 1, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API RP14F. Polyrad cable is also found in land-based oil and gas drilling rigs.

General Type P Cable Features:

  • Meets NEK 606 mud oil resistance requirements including ester-based muds
  • Meets UL 2225 crush and impact requirements of Type MC-HL cables
  • Permitted for Exposed Run "ER" (open wiring) use in accordance with NEC
  • Flexible stranding to facilitate ease of cable installation and termination
  • Temperature rated at 125°C for long life, higher ampacities and protection from thermal overloads
  • Meets cold bend test at -55°C
  • Meets cold impact test at -40°C

General Type P Cable Approvals:

  • Industry Compliances:
    • API-RP14F
    • CSA C22.2 No. 230 Type TC
    • CSA C22.2 No. 245 Type X110
    • IEEE 1580 Type P
    • IEC 60092-3
    • NEK 606 for mud oil resistance
    • UL 1309 Type X110
    • UL Listed 110°C Marine Shipboard Cable
  • Flame Test:
    • IEEE 383
    • IEEE 1202
    • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A)
    • CSA C22.2 No. 0.3 FT4

Part Number AWG SizeNo. of Cond.Ground AWG SizeNom. O.D. (in)Copper LBS/MFTApprox LBS/MFT
381780IG 8 3 3 x #14 0.7650 198 450
381790IG 6 3 3 x #12 0.7950 312 615
380560IG 4 3 3 x #12 1.0150 460 920
381800IG 2 3 3 x #10 1.1100 726 1385
381810IG 1 3 3 x #10 1.2900 890 1530
359630IG 1/0 3 3 x #10 1.6150 1098 1825
359640IG 2/0 3 3 x #10 1.6850 1362 2215
359650IG 3/0 3 3 x #8 1.8050 1755 3135
359660IG 4/0 3 3 x #8 1.9250 2509 3495
359670IG 262 3 3 x #6 2.0700 2750 4215
359680IG 313 3 3 x #6 2.2350 3235 4750
386670IG 373 3 3 x #6 2.4200 3806 5435
365690IG 444 3 3 x #6 2.6150 4975 6270
381680IG 535 3 3 x #6 2.8350 5385 7522
387920IG 646 3 3 x #4 2.9350 6565 8721
14446.037000IG 777 3 3 x #4 3.225 7815 10850