Lapp Olflex CONTROL TM Cable


Unshielded Extremely Oil-Resistant Flexible Control Cable
UL MTW & UL/CSA TC
Olflex CONTROL TM Cable Construction:
  • Conductors: Finely stranded bare copper (Class 5 fine wire)
  • Insulation: Specially blended PVC/Nylon
  • Color Code: Black with white numbers, plus green/yellow ground
  • Jacket: Specially formulated gray PVC
Olflex CONTROL TM Cable Technical Data:
  • Temperature Range:
    • UL/CSA TC: -25°C to +90°C
    • For stationary use: -40 to +105°C
    • For flexible use: -25°C to +90°C
  • Nominal Voltage:
    • UL/CSA TC: 600V
    • UL WTTC: 1000V
  • Test Voltage: 2000V
  • Minimum Bend Radius for Installation: 4 x cable diameter
Olflex CONTROL TM Cable Approvals:
  • UL:
    • TC-ER per UL 1277
    • MTW per UL 1063
    • WTTC per UL 2277
    • Bus Drop Cable (14 AWG & larger; 3c & 4c only)
    • AWM 2587 & 21098 (Oil)
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight resistant
    • Direct burial
    • NFPA 79 2012
  • NEC: Class 1, Division 2 per NEC Article 501
  • Canada:
    • c(UL) CIC/TC FT4
    • CSA AWM I/II A/B FT4
  • Additional:
    • Torsion rated for wind market (± 90°/m) & (± 150°/m)
    • Passes impact and crush test per UL 1277 (except 20 AWG)
    • CE & RoHS
Olflex CONTROL TM Cable Applications:
  • Machine tool machinery
  • Food and beverage
  • Processing equipment
  • Machine wiring for conformance to NFPA 79 2012
Olflex CONTROL TM Cable Characteristics and Benefits:
  • Industrial grade PVC jacket (Oil Res I/II)
  • Meets NFPA 79 2012 standards for wiring machinery (UL MTW)
  • Number-coded for easy connection
  • UL TC-ER approval - can be installed off the machine and into an overhead tray without conduit
  • Flexible copper stranding and pressure-extruded jacket


Need a shielded version of this cable for extra protection against EMI? See Olflex CONTROL TM CY Cable specs.
Part Number AWG SizeNo. of Cond.Nom. O.D. (in)Copper LBS/MFTApprox LBS/MFT
281803 18 3 0.2910 20 55
281804 18 4 0.3150 26 64
281805 18 5 0.3400 33 75
281807 18 7 0.3670 46 97
281809 18 9 0.4230 59 108
281812 18 12 0.4710 79 165
281818 18 18 0.5790 118 245
281819 18 19 0.5790 124 262
281825 18 25 0.6560 164 311
281603 16 3 0.3190 29 66
281604 16 4 0.3450 39 79
281605 16 5 0.3750 48 95
281607 16 7 0.4060 68 123
281609 16 9 0.4700 88 165
281612 16 12 0.5570 116 214
281618 16 18 0.6440 174 289
281619 16 19 0.6440 184 293
281625 16 25 0.7330 242 311
281403 14 3 0.3560 49 88
281404 14 4 0.3860 65 106
281405 14 5 0.4210 81 123
281407 14 7 0.4570 113 163
281409 14 9 0.5630 146 218
281412 14 12 0.6280 194 298
281419 14 19 0.7290 307 450
281425 14 25 0.8720 404 569
281203 12 3 0.4170 78 110
281204 12 4 0.4540 104 148
281205 12 5 0.4970 129 181
281207 12 7 0.5730 181 324
281209 12 9 0.6650 233 359
281003 10 3 0.4920 117 194
281004 10 4 0.5700 155 256
281005 10 5 0.6230 194 306
281007 10 7 0.6780 271 430
281009 10 9 0.7910 349 549