The Lapp VFD with Signal Cable is suitable for use in VFD drives and motor connections with temperature sensors or brake mechanisms. Other common applications include web presses, HVAC systems, and on/off or slow down/speed up applications. This cable is extremely oil and UV-resistant as well as double-shielded for extra protection. Its insulation also includes a semi-conductive layer made to withstand nonlinear power distortions.

9 items

  • $0.00 /
    • Approx LBS/MFT: 180
    • AWG Size: 16
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 /
    • Approx LBS/MFT: 254
    • AWG Size: 14
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 / 1000 FT
    • Approx LBS/MFT: 216
    • AWG Size: 14
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 / 1000 FT
    • Approx LBS/MFT: 326
    • AWG Size: 12
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 / 1000 FT
    • Approx LBS/MFT: 286
    • AWG Size: 12
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 / 1000 FT
    • Approx LBS/MFT: 406
    • AWG Size: 10
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 / 1000 FT
    • Approx LBS/MFT: 617
    • AWG Size: 8
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 /
    • Approx LBS/MFT: 848
    • AWG Size: 6
    • Cond. Material: Tinned Copper
    Order
    Add to List

Lapp VFD with Signal Cable Specifications

VFD with Signal Construction:

  • Conductors: Finely stranded tinned copper
  • Insulation: "Lapp Surge Guard" insulation system
  • Color Code: Black with white numbers, plus green/yellow ground and one black pair with white numbers
  • Jacket: Specially formulated black PVC
  • Shielding: Barrier tape; triple-layer foil tape (100% coverage); tinned copper braid (85% coverage)

VFD with Signal Ratings and Approvals:

  • Temperature Range:
    • UL/CSA TC: -25°C to 90°C
    • For stationary use: -40°C to 105°C
    • For flexible use: -25°C to 105°C
  • Nominal Voltage:
    • UL/CSA TC: 600V
    • UL WTTC: 1000V
    • UL Flexible Motor Supply: 1000V
  • UL Approval:
    • TC-ER per UL 1277
    • MTW per UL 1277
    • WTTC per UL 2277
    • AWM 20886
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight Resistant
    • Direct Burial
    • NFPA 79 2012
    • -40°C Cold Bend;-25°C Cold Impact
    • A submersible pump (14 AWG and larger)
    • Bus Drop
    • NFPA 79 2012
  • NEC Approval: Class 1 Division 2 per NEC Articles 336, 501
  • CSA Approval:
    • CSA AWM I/II A/B FT4
    • c(UL) CIC/TC FT4
  • CE Approved
  • RoHS Compliant
  • MSHA-P-07-KA050011-MSHA