25kV EPR/AIA/PVC Shielded Armored Power Cable

EPR/AIA/PVC Shielded Armored Power Cable

25kV EPR/AIA/PVC Shielded Armored Power Cable Wires
UL Type MV-105 or MC, 100% Ins. Level, 260 Mils, Three Conductor, 25kV

25kV EPR/AIA/PVC Shielded Armored Power Cable Wires Approvals:

  • National Electric Code (NEC)
  • UL 1072
  • ICEA S-93-639/NEMA WC 74
  • AEIC CS8
  • UL Listed as Type MV-105
  • IEEE 1202 (70,000 BTU/hr)/CSA FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • ICEA T-29-520 (210,000 BTU/hr)
  • ICEA T-30-520 (70,000 BTU/hr)
  • Meets EPA 40 CFR part 261 leachable lead content per TCLP method
  • OSHA acceptable

25kV EPR/AIA/PVC Shielded Armored Power Cable Wires Construction:

  • 25kV EPR/AIA/PVC Shielded Armored Power Cable Conductor:
    • 1/0 AWG thru 1000 kcmil bare, compact copper Class B strand
  • Extended Strand Shield (ESS):
    • Thermoset Semi-Conducting Extruded Stress Control lLayer over conductor
  • 25kV EPR/AIA/PVC Shielded Armored Power Cable Insulation:
    • Ethylene Propylene Rubber (EPR) colored to contrast with black conducting layer
  • 25kV EPR/AIA/PVC Shielded Armored Power Cable Extruded Insulation Shield (EIS):
    • Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • 25kV EPR/AIA/PVC Shielded Armored Power Cable Shield:
    • 5 mil annealed copper tape with a minimum 25% overlap
  • Ground:
    • Annealed bare copper Class B stranding per ASTM B8
  • 25kV EPR/AIA/PVC Shielded Armored Power Cable Armor:
    • Aluminum Interlocked Armor (AIA)
  • 25kV EPR/AIA/PVC Shielded Armored Power Cable Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) - Red

25kV EPR/AIA/PVC Shielded Armored Power Cable Wires Options:

  • Other constructions available upon request

25kV EPR/AIA/PVC Shielded Armored Power Cable Wires Applications:

  • Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is the major concern, maximum performance is demanded, space is limited, ease of installation is critical and fire resistance is necessary
  • May be installed in wet or dry locations, indoors or outdoors and in exposed or concealed work
  • May be used in cable trays or on approved supports in protected areas
  • Permitted for use in Class I, Class II Division 2, and Class III Divisions 1 and 2 per NEC Article 334

25kV EPR/AIA/PVC Shielded Armored Power Cable Wires Features:

  • Rated at 105°C wet or dry
  • Excellent heat and moisture resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical and radiation resistant
  • Excellent crush resistance
  • Cost-effective alternative to installations in conduit
  • Meets cold bend test at -25°C

 

Part Number AWG SizeGround AWG SizeNo. of Cond.Jacket ThickNom. O.D. of Cable (in)Nom. Dia. of Cond.Armor (in)Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFT
87385.267550-18 1/0 4 3 0.075 2.56 0.34 2.39 0.85 0.94 3358
87385.267600-18 2/0 4 3 0.075 2.64 0.38 2.48 0.89 0.98 3743
87385.267700-18 4/0 3 3 0.075 2.86 0.48 2.70 0.99 1.08 4807
87385.268000-18 250 3 3 0.075 2.98 0.53 2.81 1.04 1.14 5307
87385.268100-18 350 2 3 0.075 3.18 0.62 3.02 1.14 1.23 6595
87385.268250-18 500 1 3 0.085 3.46 0.74 3.28 1.26 1.35 8485
87385.268500-18 750 1/0 3 0.085 3.85 0.91 3.67 1.44 1.54 11491
87385.268750-18 1000 1/0 3 0.085 4.18 1.06 4.00 1.59 1.69 14303