5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable

EPR/AIA/PVC Shielded Armored Power Cable

5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable
UL Type MV-105 or MC, 133% / 100% Ins. Levels, 115 Mils, Three Conductor, 5kV/8kV

5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable Approvals:

  • National Electric Code (NEC)
  • UL 1072
  • ICEA S-93-639/NEMA WC 74
  • AEIC CS8
  • UL Listed as Type MV-105
  • IEEE 1202 (70,000 BTU/hr)/CSA FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • ICEA T-29-520 (210,000 BTU/hr)
  • ICEA T-30-520 (70,000 BTU/hr)
  • Meets EPA 40 CFR part 261 leachable lead content per TCLP method
  • OSHA acceptable

5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable Construction:

  • Conductor:
    • 6 AWG thru 1000 kcmil bare, compact copper Class B strand
  • Extended Strand Shield (ESS):
    • Thermoset Semi-Conductng Extruded Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) colored to contrast with black conducting shield layer
  • Extruded Insulation Shield (EIS):
    • Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • Shield:
    • 5 mil annealed copper tape with a minimum 25% overlap
  • Ground:
    • Annealed bare copper Class B stranding per ASTM B8
  • Armor:
    • Aluminum Interlocked Armor (AIA)
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) - yellow

5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable Options:

  • Other constructions available upon request

5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable Applications:

  • Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is the major concern, maximum performance is demanded, space is limited, ease of installation is critical and fire resistance is necessary
  • May be installed in wet or dry locations, indoors or outdoors and in exposed or concealed work
  • May be used in cable trays or on approved supports in protected areas
  • Permitted for use in Class I, Class II Division 2, and Class III Divisions 1 and 2 per NEC Article 334

5kV/8kV EPR/AIA/PVC Shielded Armored Power Cable Features:

  • Rated at 105°C wet or dry
  • Excellent heat and moisture resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical and radiation resistant
  • Excellent crush resistance
  • Cost-effective alternative to installations in conduit
  • Meets cold bend test at -25°C

 

Part Number AWG SizeGround AWG SizeNo. of Cond.Jacket ThickNom. O.D. of Cable (in)Nom. Dia. of Cond.Armor (in)Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFT
87365.265300-18 6 6 3 0.050 1.44 0.17 1.33 0.42 0.49 1133
87365.265200-18 4 6 3 0.050 1.54 0.21 1.43 0.46 254 1354
87365.265100-18 2 6 3 0.060 1.77 0.27 1.64 0.51 0.59 1819
87365.267550-18 1/0 4 3 0.060 1.92 0.34 1.79 0.58 0.66 2364
87365.267600-18 2/0 4 3 0.060 2.00 0.38 1.87 0.62 0.70 2696
87365.267700-18 4/0 3 3 0.060 2.22 0.48 2.09 0.72 0.80 3687
87365.268000-18 250 3 3 0.060 2.34 0.52 2.21 0.77 0.85 4165
87365.268100-18 350 2 3 0.075 2.57 0.62 2.41 0.87 0.95 5436
87365.268250-18 500 1 3 0.075 2.84 0.74 2.64 0.99 1.07 7170
87365.268500-18 750 1/0 3 0.085 3.25 0.91 3.06 1.17 1.25 10084
87365.268750-18 1000 1/0 3 0.085 3.57 1.07 3.39 1.33 1.40 12793