CSA ACWU90 Single Conductor Armored Control Cable (600 V)

600 Volt ACWU90 Armored Control Cable


XLPE/AIA/PVC Single Conductor Armored Control Cable
600V, CSA ACWU90 (-40°C)

Product Approvals:

  • CSA Standard C22.2 No. 51 and No. 174
  • CSA FT1 and FT4
  • IEEE 1202 (70,000 BTU/hr)CSA FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • ICEA T-30-520 (70,000 BTU/hr)
  • Hazardous Location Rating: HL
  • Meets EPA 40 CFR, part 261 for leachable lead content per TCLP method
  • OSHA acceptable

CSA ACWU90 Single Conductor Armored Control Cable (600 V) Construction:

  • Conductor: 4/0 AWG thru 1000 kcmil bare ACM aluminum (8000 series Aluminum) compact Class B strand
  • Ground (Bonding) Conductor: The conductor is a concentric serving of solid bare aluminum (ACM) wires applied over the insulation
  • Insulation: Cross-Linked Polyethylene (XLPE) Type RW90; Color-coded: Black
  • Armor: Aluminum Interlocked Armor (AIA)
  • Jacket: ACID-FLAME CHECK flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)- Black

CSA ACWU90 Single Conductor Armored Control Cable (600 V) Applications:

  • For exposed and concealed wiring in dry, damp or wet locations
  • For use in ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations
  • For direct earth burial (with protection as required by inspections authority)
  • For wiring in all hazardous locations when used with certified HL cable glands
  • Cost-effective alternative to installation in conduit
  • Typical vertical installations include mine shafts, tall commercial buildings, inclined tunnels and vertical cable trays (Note that the overall jacket is required for all damp and wet locations and for all corrosive environments: CE Code part 1 Rules 12-708 and 22-200)

CSA ACWU90 Single Conductor Armored Control Cable (600 V) Features:

  • Rated at 90°C wet or dry
  • Excellent crush, oil and chemical resistance
  • Provides long service life
  • Cost-effective alternative to installations in conduit
  • Meets cold bend and impact tests at -40°C
Part Number AWG SizeNom. Insul. Thick. (in)Nom. O.D. (in)Approx LBS/MFTArmor (in)Ampacity @ 30°CGround AWG Size
5640.5077-18 4/0 0.055 1.0360 504 0.940 300 2
5640.508-18 250 0.065 1.1030 600 1.007 330 1
5640.5081-18 350 0.065 1.1990 745 1.103 415 1/0
5640.50825-18 500 0.065 1.3170 952 1.221 515 2/0
5640.50835-18 600 0.080 1.4300 1099 1.334 585 2/0
5640.5085-18 750 0.080 1.5250 1305 1.429 670 3/0
5640.50875-18 1000 0.080 1.7790 1704 1.667 800 3/0