CSA ACWU90 Three Conductor Armored Control Cable (600 V)

600 Volt ACWU90 Armored Control Cable


XLPE/AIA/PVC Three Conductor Armored Control Cable
600V, CSA ACWU90 (-40°C)

Product Approvals:

  • CSA Standard C22.2 No. 51 and No. 174
  • CSA FT1 and FT4
  • IEEE 1202 (70,000 BTU/hr)CSA FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr
  • ICEA T-30-520 (70,000 BTU/hr)
  • Hazardous Location Rating: HL
  • Meets EPA 40 CFR, part 261 for leachable lead content per TCLP method
  • OSHA acceptable

CSA ACWU90 Three Conductor Armored Control Cable (600 V) Construction:

  • Conductor: 6 AWG thru 750 kcmil bare ACM aluminum (8000 series Aluminum) compact Class B strand
  • Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare aluminum (ACM) conductor
  • Insulation: Cross-Linked Polyethylene (XLPE) Type RW90; Color-coded: Black, White and Red
  • Armor: Aluminum Interlocked Armor (AIA)
  • Jacket: ACID-FLAME CHECK flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)- Black

CSA ACWU90 Three Conductor Armored Control Cable (600 V) Applications:

  • For exposed and concealed wiring in dry, damp or wet locations
  • For use in ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations
  • For direct earth burial (with protection as required by inspections authority)
  • For wiring in all hazardous locations when used with certified HL cable glands
  • For service entrance installations

CSA ACWU90 Three Conductor Armored Control Cable (600 V) Features:

  • Rated at 90°C wet or dry
  • Excellent crush, oil and chemical resistance
  • Provides long service life
  • Cost-effective alternative to installations in conduit
  • Meets cold bend and impact tests at -40°C
Part Number AWG SizeNo. of Cond.Nom. Insul. Thick. (in)Nom. O.D. of Cable (in)Approx LBS/MFTArmor (in)Ampacity @ 30°CGround AWG Size
5640.5153-18 6 3 0.045 0.879 325 0.783 55 8
5640.5151-18 2 3 0.045 1.093 530 0.997 95 6
5640.51755-18 1/0 3 0.055 1.207 637 1.111 120 4
5640.5176-18 2/0 3 0.055 1.375 850 1.279 145 4
5640.51765-18 3/0 3 0.055 1.476 996 1.380 165 4
5640.5177-18 4/0 3 0.055 1.584 1161 1.488 185 4
5640.518-18 250 3 0.065 1.839 1493 1.727 215 2
5640.5181-18 350 3 0.065 2.043 1885 1.931 260 2
5640.51825-18 500 3 0.065 2.304 2485 2.192 330 1
5640.51835-18 600 3 0.080 2.563 3035 2.424 370 1