add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

EPR/PVC Power Cable with Copper Tape Shield (15kV)

EPR/PVC Power Cable with Copper Tape Shield (15kV)
UL Type MV-105, 133% Ins. Level, 220 Mils, 15kV

Product Approvals:

  • Industry Approvals:
    • National Electric Code (NEC)
    • UL 1072
    • ICEA S-93-639/NEMA WC74
    • ICEA S-97-682
    • AEIC CS8
    • UL Listed as Type MV-105 for use in accordance with NEC
    • Sizes 1/0 AWG and larger are listed and marked "Sunlight-Resistant FOR CT USE" i naccordance with NEC
    • IEEE 1202 (70,000 BTU/hr)/CSA FT4
    • Meets EPA 40 CFR, Part 2671 for leachable lead content per TLCP method
    • OSHA acceptable
  • Optional Flame Tests:
    • ICEA T-29-520 (210,000 BTU/hr)

EPR/PVC Power Cable with Copper Tape Shield (15kV) Construction:

  • Conductor:
    • 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand
  • Extended Strand Shield (ESS):
    • Extruded Thermoset Semi-Conducting Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers
  • Extruded Insulation Shield (EIS):
      Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • Metallic Shield:
    • 5 mil annealed copper tape with an overlap of 25%
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)

EPR/PVC Power Cable with Copper Tape Shield (15kV) Options:

  • PVC jacket color other than black
  • Flame Retardant, Chlorinated Polyethylene (CPE) jacket
  • Low-Smoke, Halogen-Free (LSZH) jacket
  • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-0-610
  • 100% insulation level

EPR/PVC Power Cable with Copper Tape Shield (15kV) Applications:

  • Installed in a broad range of commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and fossil fuel utility generating stations
  • Suitable for use in wet or dry locations, when installed in accordance with NEC
  • For use in aerial, direct burial, conduit, open tray and underground duct installations
  • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5)

EPR/PVC Power Cable with Copper Tape Shield (15kV) Features:

  • Rated at 105°C
  • Excellent heat and moisture resistance
  • Excellent flame resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical resistant
  • Meets cold bend test at -35°C

 

Part Number AWG SizeJacket ThickNom. O.D. (in)Nom. Dia. of Cond.Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFTAmpacity (Duct in Air)Ampacity (Underground)Ampacity (Tray)
85155.065100-18 2 0.080 0.99 0.27 0.710 0.800 658 165 165
85155.065050-18 1 0.080 1.02 0.31 0.745 0.830 733 190 185
85155.067550-18 1/0 0.080 1.06 0.34 0.780 0.865 825 215 215 220
85155.067600-18 2/0 0.080 1.10 0.38 0.820 0.905 938 255 245 250
85155.067650-18 3/0 0.080 1.14 0.43 0.865 0.955 1078 290 275 290
85155.067700-18 4/0 0.080 1.21 0.48 0.920 1.005 1261 330 315 335
85155.068000-18 250 0.080 1.25 0.53 0.970 1.060 1407 265 245 270
85155.068100-18 350 0.080 1.35 0.62 1.070 1.155 1783 440 415 460
85155.068250-18 500 0.080 1.47 0.74 1.190 1.275 2331 535 500 575
85155.068500-18 750 0.080 1.65 0.91 1.370 1.460 3234 655 610 745
85155.068750-18 1000 0.110 1.86 1.06 1.520 1.610 4219 755 690 890