Halogen Free, Flame Retardant Remote Installation Bus Cables

Halogen Free, Flame Retardant Remote Installation Bus Cables

Halogen Free, Flame Retardant Remote Installation Bus Cable Product Approvals:

  • CE
  • RoHS Hook-up WireRoHS Compliant

Halogen Free, Flame Retardant Remote Installation Bus Cable Construction:

  • Color Code: DIN 47100 (pairs), 18 AWG: red, blue and green-yellow earth wire
  • Stranding: Twisted to pairs (< 24 AWG)
  • Screen: Tinned copper braiding
  • Conductor: 0.22 mm2: bare copper strands + 1.00 mm2: bare copper strands
  • Core Insulation: Halogen Free and Fire Protected Thermoplastic
  • Wrapping: PETP foil
  • Outer Jacket: Halogen Free and Fire Protected Thermoplastic
  • Jacket Color: Purple

Halogen Free, Flame Retardant Remote Installation Bus Cable Applications:

  • The Halogen Free, Flame Retardant Remote Installation Bus Cable may be applied as a data cable in the sensor/actor level of industrial communication where the power supply for the Bus logic of the subsequent participants is carried.

Halogen Free, Flame Retardant Remote Installation Bus Cable Ratings:

  • Nominal Voltage: max. 350 V
  • Testing Voltage: 1500 V
  • Minimum Bending Radius: 7.5 x O.D.
  • Characteristic Impedance at 0.064 MHz: 120 O ± 20%
  • Characteristic Impedance > 1 MHz: 100 O ± 15O
  • Temperature Range:
    • Static: -40/+85 °C
    • Flexing: -30/+85 °C

Halogen Free, Flame Retardant Remote Installation Bus Cable Technical Data:

  • Zero Halogen: DIN VDE 0472
  • Burning Characteristics: Halogen Free Remote Installation Bus has no flame propagation, and is flame retardant and self-extinguishing.
  • Corrosivity: No development of corrosive conflagration gases
  • Smoke Density: IEC 61034 / EN 61034
  • Flexibility: Good
  • Application In Cable Tracks: Not recommended for Halogen Free, Flame Retardant Remote Installation Bus
  • Weather Resistance: Good
Part Number AWG SizeNo. of PairsApprox LBS/MFTAWG (Power Cond.)No. of Cond. (Power Cond.)Nom. O.D. of Cable (in)
330531105-54 24 3 63 18 3 0.276