FR-EPR/XL-CPE Unshielded Control Cable (Type TC)

FR-EPR/XL-CPE Unshielded Cable

We're sorry but FR-EPR/XL-CPE Unshielded Control Cable (Type TC) is no longer available for purchase. Please call us at 800-472-4655 or email us and we will help you find a suitable alternative.

FR-EPR/XL-CPE Unshielded Control Cable (Type TC)
UL Type TC - E-2 Color code, 600 V

FR-EPR/XL-CPE Unshielded Control Cable (Type TC) Product Approvals:

  • Industry Approvals
    • UL 1277 Type TC
    • UL 1581
    • ICEA S-73-532
    • ICEA S-95-658/NEMA WC70
  • Flame Tests Compliances:
    • UL 1581 VW-1
    • UL 1277
    • IEEE 383
    • IEEE 1202
    • CSA FT4
    • ICEA T-29-520
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

FR-EPR/XL-CPE Unshielded Control Cable (Type TC) Construction:

  • Conductor:
    • 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
    • Class B stranding per ASTM B8
  • Insulation:
    • Flame retardant Ethylene Propylene Rubber (FR-EPR) Type II
    • Color coded per ICEA Method 1; Table E-2 (Does not include white or green)
  • Jacket:
    • Cross-Linked Chlorinated Polyethylene (XL-CPE)

FR-EPR/XL-CPE Unshielded Control Cable (Type TC) Options:

  • 2kV version
  • Bare copper conductor
  • Class C stranding
  • Insulated or uninsulated ground conductors
  • Overall shielded multi conductor
  • Duralox® aluminum interlocked armor
  • E-1 Color Code
  • Flame retardant Polyvinyl Chloride (PVC) jacket
  • Thermoplastic Low-Smoke, Zero-Halogen (LSZH) jacket
  • Flame retardant Thermoplastic Chloronated Polyethylene (CPE)
  • Other constructions available upon request

FR-EPR/XL-CPE Unshielded Control Cable (Type TC) Applications:

  • In free air, raceways or direct burial
  • In wet or dry locations
  • At temperature as low as -35°C
  • Permitted for use in Class I Division 2 industrial hazardous locations per NEC

FR-EPR/XL-CPE Unshielded Control Cable (Type TC) Features:

  • Rated at 90°C, wet or dry
  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Excellent physical, thermal and electrical properties
  • Excellent moisture resistance
  • Outstanding resistance to crush, compression cuts and heat deformation
  • Excellent flame resistance
  • Excellent low temperature cold bend characteristics
  • Good abrasion resistance
  • Low moisture absorption characteristics
  • "Heavy Duty" rating per ICEA standards
  • Meets cold bend test at -35°C
  • Meets the crush and impact requirements of Type MC cable for 2 AWG and larger
Part Number AWG SizeNo. of Cond.Conductor StrandingNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Jacket ThickApprox Dimension
183095-18 18 2 7/.0152 37 .025 .045 .192 x .290
171665-18 18 2 7/.0152 0.2950 45 .025 .045
171670-18 18 3 7/.0152 0.3100 55 .025 .045
171675-18 18 4 7/.0152 0.3400 67 .025 .045
171680-18 18 5 7/.0152 0.3650 79 .025 .045
171685-18 18 7 7/.0152 0.3950 97 .025 .045
171690-18 18 9 7/.0152 0.4550 123 .025 .045
171695-18 18 10 7/.0152 0.4850 137 .025 .045
171700-18 18 12 7/.0152 0.5100 153 .025 .045
171705-18 18 15 7/.0152 0.5800 202 .025 .060
171710-18 18 19 7/.0152 0.6250 243 .025 .060
171715-18 18 25 7/.0152 0.7200 301 .025 .060
171720-18 18 30 7/.0152 0.7700 345 .025 .060
171725-18 18 37 7/.0152 0.8300 414 .025 .060
183100-18 16 2 7/.0192 46 .025 .045 .204 x .314
171730-18 16 2 7/.0192 0.3200 55 .025 .045
171735-18 16 3 7/.0192 0.3400 69 .025 .045
171740-18 16 4 7/.0192 0.3650 85 .025 .045
171745-18 16 5 7/.0192 0.4000 102 .025 .045
171750-18 16 7 7/.0192 0.4300 127 .025 .045
171755-18 16 9 7/.0192 0.5000 162 .025 .045
171760-18 16 10 7/.0192 0.5650 197 .025 .060
171765-18 16 12 7/.0192 0.5900 221 .025 .060
171770-18 16 15 7/.0192 0.6400 270 .025 .060
171775-18 16 19 7/.0192 0.6900 327 .025 .060
171780-18 16 25 7/.0192 0.7950 424 .025 .060
171785-18 16 30 7/.0192 0.8900 508 .025 .080
171790-18 16 37 7/.0192 0.9550 609 .025 .080
131065-18 14 2 7/.0242 68 .030 .045 .230 x .365
171795-18 14 2 7/.0242 0.3700 76 .030 .045
131070-18 14 3 7/.0242 0.3900 97 .030 .045
124120-18 14 4 7/.0242 0.4250 120 .030 .045
131075-18 14 5 7/.0242 0.4650 145 .030 .045
131080-18 14 7 7/.0242 0.5050 183 .030 .045
171800-18 14 9 7/.0242 0.6200 254 .030 .060
124145-18 14 12 7/.0242 0.7000 323 .030 .060
171815-18 14 19 7/.0242 0.8150 477 .030 .060
131095-18 14 25 7/.0242 1.0000 645 .030 .080
171820-18 14 30 7/.0242 1.0500 746 .030 .080
171825-18 14 37 7/.0242 1.1300 919 .030 .080
171830-18 12 2 7/.0305 88 .060 .045 .250 x .400
171835-18 12 2 7/.0305 0.4100 99 .060 .045
171840-18 12 3 7/.0305 0.4350 129 .060 .045
171845-18 12 4 7/.0305 0.4750 163 .060 .045
131100-18 12 5 7/.0305 0.5200 198 .060 .045
171850-18 12 7 7/.0305 0.5950 269 .060 .060
171855-18 12 9 7/.0305 0.6950 351 .060 .060
171865-18 12 12 7/.0305 0.7800 443 .060 .060
171875-18 12 19 7/.0305 0.9550 703 .060 .080
171880-18 12 25 7/.0305 1.1150 875 .060 .080
171885-18 12 30 7/.0305 1.1500 1017 .060 .080
171890-18 12 37 7/.0305 1240 1421 .060 .080
171895-18 10 2 7/.0385 119 .030 .045 .270 x .445
171900-18 10 2 7/.0385 0.4550 134 .030 .045
171905-18 10 3 7/.0385 0.4850 178 .030 .045
132495-18 10 4 7/.0385 0.5600 243 .030 .060
171910-18 10 5 7/.0385 0.6150 295 .030 .060
171915-18 10 7 7/.0385 0.6700 382 .030 .060
171920-18 10 9 7/.0385 0.7650 492 .030 .060
171930-18 10 12 7/.0385 0.9050 662 .030 .080