add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

MIL-C-24643/49 (LSTNW and LSTNWA)

MIL-C-24643 Low Smoke Shipboard Cable

Low Smoke Power and Lighting Shipboard Cable
MIL-C-24643/49
LSTNW (Unarmored)
LSTNWA (Armored)

MIL-C-24643/49 (LSTNW and LSTNW) Approvals:

  • M24643/49
  • MIL-I-45208A
  • MIL-STD-790

MIL-C-24643/49 (LSTNW and LSTNW) Description:

  • Three conductor
  • Non-watertight cable with surface marking
  • Non-flexing
  • Service: 1000 Volts

MIL-C-24643/49 (LSTNW and LSTNW) Cable Construction:

  • Conductor:
    • 7 AWG and smaller: Uncoated copper with opaque white separator (Class B stranding per ASTM B8)
    • 1 AWG & 3 AWG: Uncoated copper with opaque white separator (Class C stranding per ASTM B8)
    • 1/0 AWG & 3/0 AWG: Uncoated copper with opaque white separator (Class D stranding per ASTM B8)
  • Insulation: Cross-linked Polyethylene (XLPE)
  • Jacket: Low-Smoke, Zero-Halogen Cross-Linked Polyolefin )
  • Armor (LSTNWA): Braided Aluminum

MIL-C-24643/49 (LSTNW and LSTNW) Applications:

  • Cables are multi conductor constructions suitable for non-watertight, non-flexing service.
  • For use in shipboard power, lighting or weapons control system interconnection, except where unusual circuit parameters require a special type of cable.
  • Shall be used only for runs that are either totally within one compartment or totally within two contiguous comparments.
  • Shall not be used where a watertight deck or bulkhead below flooding water level II (FWL-II) is penetrated.

MIL-C-24643/49 (LSTNW and LSTNW) Features & Benefits:

  • Non-watertight for mission-critical environments.
  • Thermoset system for advanced mechanical fortification.
  • Low-Smoke, Zero-Halogen system maintains circuit integrity as a result of minimal smoke generation, acid gas and toxicity.
Part Number AWG SizeNo. of Cond.Approx LBS/MFTMil-Spec #Conductor StrandingMax O.D. (in)Ampacity (Cond.) @ 50°
LSTNW-3 16 3 85 M24643/49-01-UN 7/.0192 0.411 10
LSTNW-4 14 3 107 M24643/49-02-UN 7/.0242 0.449 17
LSTNW-9 10 3 240 M24643/49-03-UN 7/.0385 0.625 36
LSTNW-14 9 3 271 M24643/49-04-UN 7/.0732 0.670 47
LSTNW-23 7 3 390 M24643/49-05-UN 7/.0545 0.760 64
LSTNW-50 3 3 793 M24643/49-06-UN 19/.0526 0.969 101
LSTNW-75 1 3 1200 M24643/49-07-UN 37/.0476 1.134 136
LSTNW-100 1/0 3 1452 M24643/49-08-UN 61/.0416 1.266 160
LSTNW-150 3/0 3 2218 M24643/49-09-UN 61/.0524 1.515 235
LSTNWA-3 16 3 107 M24643/49-01-AN 7/.0192 0.461 10
LSTNWA-4 14 3 130 M24643/49-02-AN 7/.0242 0.499 17
LSTNWA-9 10 3 271 M24643/49-03-AN 7/.0385 0.675 36
LSTNWA-14 9 3 306 M24643/49-04-AN 7/.0732 0.720 47
LSTNWA-23 7 3 427 M24643/49-05-AN 7/.0545 0.810 64
LSTNWA-50 3 3 868 M24643/49-06-AN 19/.0526 1.019 101
LSTNWA-75 1 3 1276 M24643/49-07-AN 37/.0476 1.184 136
LSTNWA-100 1/0 3 1510 M24643/49-08-AN 61/.0416 1.316 160
LSTNWA-150 3/0 3 2277 M24643/49-09-AN 61/.0524 1.565 235