XLPE/ARCTIC-FLEX Unshielded Control Cable

RW90/XLPE Unshielded Cable

XLPE/ARCTIC-FLEX Unshielded Control Cable
UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC, 600V

XLPE/ARCTIC-FLEX Unshielded Control Cable Product Approvals:

  • Industry Approvals:
    • ICEA S-73-532
    • ICEA S-95-658/NEMA WC70
    • UL 44 Type XHHW-2
    • UL 1277 Type TC-ER for 3 or more conductors
    • UL 1581
    • CSA C22.2 No. 38 XLPE RW90
    • CSA C22.2 No 230 Type TC
  • Flame Tests Approvals:
    • UL 1581 VW-1
    • UL 1277
    • IEEE 383
    • IEEE 1202
    • CSA FT4
  • Other Compliances:
    • Meets EPA 10 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

XLPE/ARCTIC-FLEX Unshielded Control Cable Construction:

  • Conductor:
    • 14 AWG thru 10 AWG tinned, annealed copper per ASTM B33
    • Class B stranding per ASTM B8
  • Insulation:
  • Jacket:
    • Flame Retardant and sunlight resistant Arctic-grade Polyvinylchloride (PVC)

XLPE/ARCTIC-FLEX Unshielded Control Cable Options:

  • Bare copper, class C stranding
  • Uninsulated ground (bonding) conductors
  • Overall shielded multi conductors
  • Optional color code as specified per CSA standard C22.2 No. 38 for two to four conductor cable
  • Non-UL 1000 volt CSA type RW90 XLPE, CSA Type TC
  • Other constructions available upon request

XLPE/ARCTIC-FLEX Unshielded Control Cable Applications:

  • Industrial lighting, control and signaling circuits
  • Approved for direct burial, Class I, Div 2 industrial hazardous locations per NEC for UL Type TC cables. In Canada, protection may be required by inspection authority per Canadian electrical code.
  • Permitted for Exposed Run 'ER' use in accordance with NEC for 3 or more conductors
  • Approved for cable in tray, industrial hazardous locations, Class I, Zone 2 and Class II, Division 2 per CEC rules 18-156 and 18-252 when used with certified HL glands.

XLPE/ARCTIC-FLEX Unshielded Control Cable Features:

  • Rated at 90°C wet or dry
  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Meets CSA cold impact test at -40°C
  • Meets ICEA and CSA cold bend test at -65°C
  • Meets the crush and impact requirements of Type MC
Part Number AWG SizeNo. of Cond.Conductor StrandingNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Jacket Thick
173670-18 14 2 7/.0242 0.4050 71 .030 .045
173675-18 14 3 7/.0242 0.3900 90 .030 .045
173680-18 14 4 7/.0242 0.4250 113 .030 .045
173685-18 14 5 7/.0242 0.4650 140 .030 .045
173690-18 14 7 7/.0242 0.5900 176 .030 .045
173695-18 14 9 7/.0242 0.6200 245 .030 .060
173700-18 14 12 7/.0242 0.6800 302 .030 .060
173705-18 14 19 7/.0242 0.8000 460 .030 .060
173710-18 14 25 7/.0242 0.9850 641 .030 .060
173715-18 14 30 7/.0242 1.0500 740 .030 .080
173720-18 14 37 7/.0242 1.1300 888 .030 .080
173725-18 12 2 7/.0305 0.4100 96 .030 .045
173730-18 12 3 7/.0305 0.4350 125 .030 .045
173735-18 12 4 7/.0305 0.4750 157 .030 .045
173740-18 12 5 7/.0305 0.5200 191 .030 .045
173745-18 12 7 7/.0305 0.5950 260 .030 .060
173750-18 12 9 7/.0305 0.6950 340 .030 .060
173755-18 12 12 7/.0305 0.7800 429 .030 .060
173760-18 12 19 7/.0305 0.9300 681 .030 .080
173765-18 12 25 7/.0305 1.0950 885 .030 .080
173770-18 12 30 7/.0305 1.1500 1005 .030 .080
173775-18 12 37 7/.0305 1.2400 1185 .030 .080
173780-18 10 2 7/.0385 0.4550 130 .030 .045
173785-18 10 3 7/.0385 0.4850 168 .030 .045
173790-18 10 4 7/.0385 0.5150 229 .030 .060
173795-18 10 5 7/.0385 0.6150 281 .030 .060
173800-18 10 7 7/.0385 0.6700 377 .030 .060
173805-18 10 9 7/.0385 0.7850 479 .030 .060
173810-18 10 12 7/.0385 0.8950 644 .030 .080