add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

Single Conductor Unshielded Armored Power Cable (5kV)

XLPE/PVC/AIA/PVC Unshielded Armored Power Cable 5kV


XLPE/PVC/AIA/PVC Single Conductor Unshielded Armored Power Cable
5kV, CSA TECK90

Product Approvals:

  • CSA Standard C22.2 No. 131 and No. 174
  • CSA Approval number: LR1781
  • CSA FT1 and FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr
  • IEEE 1202 (70,000 BTU/hr) CSA FT4
  • ICEA T-30-520 (70,000 BTU/hr)
  • Hazardous Location Rating: HL
  • Meets EPA 40 CFR, part 261 for leachable lead content per TCLP method
  • OSHA acceptable

Single Conductor Unshielded Armored Power Cable (5kV) Construction:

  • Conductor 6 AWG thru 1000 kcmil bare copper Class B strand
  • Ground (Bonding) Conductor: Concentric serving of solid bare copper wires applied over the insulation
  • Insulation: Cross-linked Polyethylene (XLPE) Type RW90; Black
  • Inner Jacket: Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)-Black
  • Armor: Aluminum Interlocked Armor (AIA)
  • Overall Jacket: ACID-FLAME CHECK flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)-Orange

Single Conductor Unshielded Armored Power Cable (5kV) Applications:

  • For exposed and concealed wiring in dry, damp or wet locations
  • For use in ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations
  • For direct earth burial (with protection as required by inspection authority)
  • For wiring in all hazardous locations when used with certified HL cable glands

Single Conductor Unshielded Armored Power Cable (5kV) Features:

  • Rated at 90°C wet or dry
  • Excellent crush, oil and chemical resistance
  • Provides long service life
  • Meets cold bend and impact tests at -40°C

Single Conductor Unshielded Armored Power Cable (5kV) Options:

  • Other constructions available upon request
Part Number AWG SizeNom. O.D. (in)Approx LBS/MFTArmor (in)Ampacity @ 30°CGround AWG Size
8748.0503-18 6 0.8500 370 0.76 100 8
8748.0502-18 4 0.9300 490 0.84 135 6
8748.05015-18 3 0.9500 540 0.86 155 6
8748.0501-18 2 0.9800 590 0.89 180 6
8748.05005-18 1 1.0200 720 0.93 210 4
8748.05255-18 1/0 1.0600 800 0.96 245 4
8748.0526-18 2/0 1.1300 900 1.03 285 4
8748.05265-18 3/0 1.1800 1130 1.08 330 3
8748.0527-18 4/0 1.2600 1330 1.16 385 3
8748.053-18 250 1.3400 1530 1.24 425 2
8748.0531-18 350 1.4400 1960 1.34 530 1
8748.05325-18 500 1.5900 2570 1.49 660 1/0
8748.0535-18 750 1.7800 3900 1.68 845 2/0
8748.05375-18 1000 1.9600 4930 1.86 1000 2/0