VFD Double Insulated Shielded Tray Cable

Variable Frequency Drive Cable (VFD Cable)

VFD Double Insulated Shielded Tray Cable

Insulated Shielded Tray Cable Approvals:

  • CE
  • Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4
  • AWM Style 21179 105°C 1000V
  • c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4
  • CSA AWM I/II A/B 90°C 1000V FT1 FT2
  • RoHS Hook-up WireRoHS Compliant

Insulated Shielded Tray Cable Construction:

  • Conductor: Tinned copper strands
  • Insulation: Special formulated PVC/Nylon
  • Color Code: Black conductors with consecutive white numbers and green-yellow earth wire.
  • Stranding: In layers.
  • Inner Jacket: Special formulated PVC, color black
  • Screen: Double shield, alu foil and tinned copper braiding
  • Jacket Material: Special sunlight and oil resistant PVC
  • Jacket Color: Black

Insulated Shielded Tray Cable Applications:

  • Insulated Shielded Tray Cable is designed for automated servo systems, and is suitable for tray cable application and also as Control and Instrumentation Cable. The VFD can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50' of open wiring to make installations less cumbersome. There is an outer PVC jacket and both a foil and a braid shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. Insulated Shielded Tray Cable can be used without jacket (exposed runs) and is permitted to be used in hazardous (classified) locations class I, Division 2.

Insulated Shielded Tray Cable Technical Data:

  • Nominal Voltage:
    • (UL)/c(UL): 600V
    • UL-AWM/CSA-AWM: 1000 v
  • Testing Voltage:
    • Conductor/Conductor: 7500 V
    • Conductor/Screen: 3000 V
  • Minimum Bending Radius: 7.5 x O.D.
  • Temperature Range:
    • UL-AWM: up to +105°C
    • (UL)/c(UL)/CSA-AWM: up to +90°C
  • Burning Characteristics: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2
  • Oil Resistant: Yes
  • Sunlight Resistance: Yes
  • Exposed Runs: Yes
  • Direct Burial: Yes
Part Number AWG SizeNo. of Cond.Conductor StrandingApprox LBS/MFTNom. O.D. of Cable (in)Nom. Dia. of Cond.
4310902-54 18 4 30/32 95 0.390 0.097
4310802-54 16 4 29/30 114 0.417 0.108
4310702-54 14 4 46/30 155 0.461 0.124
4310602-54 12 4 75/30 196 0.508 0.147
4310502-54 10 4 113/30 330 0.677 0.186
4310402-54 8 4 180/30 519 0.874 0.250
4310302-54 6 4 287/30 731 1.035 0.309
4310202-54 4 4 448/30 1027 1.213 0.380
4310102-54 2 4 691/30 1408 1.382 0.449