add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

Data Master® Composite Aerospace Data Cables

Part Number Nom. Dia. of Cond.Dielectric (in)Nom. O.D. of Cable (in)Nom. Imp.Nom. Cap. (pF/ft)Approx LBS/MFT
AWC-USB 90-26/22S 0.0187 0.042 0.200 90 13.0 29
AWC-1394-110-24/SS 0.0150 0.050 0.250 110 11.5 40

Data Master® Cable*
Aerospace Cable


Allied Wire & Cable carries the highest quality Aerospace cable available. Data Master® Composite Aerospace Data Cable is a signaling cable and power cable in one. That means you only need to install one cable for both purposes, which reduces weight onboard, cost of manufacturing and lessens the load involved in repairs. Data Master® Composite Aerospace Data Cable can also be manufactured with a shield depending on your application’s needs.

lsc5fs-4 spec

LSC5FS-4 Construction:

  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Tape: Foam Polypropylene (PE) 25% Overlap
  • Drain: 24 AWG Stranded Tinned Copper 
  • Tape: Flame Retardant Tape 25% Overlap
  • Tape: Fiberglass Tape 25% Overlap
  • Tape: Marker Tape 

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

lsc5os-4 spec

LSC5OS-4 Construction:

  • Category 5 Defense-Link™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Tape: Polypropylene (PE) 25% Overlap
  • Shield: Aluminum/Polyester
  • Braid: 36 AWG Tinned Copper

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5OSW-4 Construction:

  • Category 5e Shielded Defense-Link™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Gel: Cable Filled with Water Blocking
  • Both Tapes: Water Blocking Tape
  • Braid: 36 AWG Tinned Copper

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5POS-4 Compose Construction:

LSC5POS-4

  • Category 5e Shielded Defense-Link ™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to Varying Lays
  • Cable Assembly: 4 Pairs Cabled With Separator
  • 36 AWG Tinned Copper Braid
  • Tape: Polypropylene 25% Overlap

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2017-354

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown