add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

CampusLink™ LT Gel Single Jacket Riser

Sample

CampusLink LTTM Loose tube | indoor-outdoor riser | gel buffer tubes | dielectric (single jacket) with aluminum interlock armor 12-62.5/125 multimode fibers per buffer tube | 48 fibers total (printed in feet)

F DRLTB AJ 12 G6 048 M2
1 - Length Markings 2 - Product  Family 3 - Construction 4 - Fiber Grouping 5 - Fiber Type 6 - Fiber Count 7 - Fiber Grade

 

Choose from a range of single-mode and multi-mode connector options, or order pigtails. You can also specify fiber count (01-96), cable assembly length (001-999), and more.

CampusLink LT Gel Single Jacket Riser Fiber Optic Cable is for use in indoor-outdoor applications. This cable is Dielectric, belongs to Prysmian/Draka DRLTB series, and it rated as OFNR/FT4. The OFNR rating is an identifier that shows this is optical fiber, nonconductive, riser. The fiber count available for this fiber optic cable is 2 to 144.

PART NUMBER CONSTRUCTION for GEL SINGLE JACKET RISER FIBER OPTIC CABLE

 

1. Length Markings

F = feet

M = meters

 

2. Product Family

Riser/FT4 ⎸Gel Filled Buffer Tubes ⎸OFNR/FT4

  • DRLTB = Indoor/Outdoor Riser All-dielectric (single jacket) OFNR / FT4

 

3. Construction

(blank) = none

AJ = Jacketed Aluminum (use with DRLTB)

SJ = Jacketed Steel (use with DRLTB)

 

4. Fiber Grouping

12 = 12f per unit or tube


 

FIBER INFORMATION

 

5. Fiber Type

Single-Mode

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

 

Multi-Mode

Wavelength (nm)

Bandwidth (MHz)

1 GbE Dist

(m)

10 GbE Dist (m)

G6 = OM1 (62.5μm)

850/1300

200/500

300/550

33/___

G5 = OM2+ BIF (50μm)

850/1300

700/500

800

150/___

G3 = OM3 BIF (50μm)

850/1300

1500/500

1000

300/___

G4 = OM4 BIF (50μm)

850/1300

3500/500

1100

550/___


 

6. Fiber Count

002 to 144 fibers

For full specs on per fiber count, see fiber optic cable spec table below
 

7. Fiber Grade

Single-Mode

Attenuation (dB/km)

Wavelength (nm)

Fiber Type

E1 = 0.40/0.40/0.30

1310/1383/1550

HB, ES, or CE

E3 = 0.35/0.35/0.25

1310/1383/1550

HB, ES, B1, B2 or CE

 

Multi-Mode

Attenuation (dB/km)

Wavelength (nm)

M2 = 3.5/1.0

850/1300

M3 = 3.0/1.0

850/1300

 

 

Temperature Range

  • Shipping and Storage: Riser -58°F to +158°F (-50°C to +70°C)
  • Installation: Riser +14°F to +140°F (-10°C to +60°C)
  • Operation: Riser -58°F to +158°F (-50°C to +70°C)
  • Mechanical Specifications:
    • Maximum installation load: 600 lbf (2670 N)
    • Maximum operation load: 180 lbf (801 N)

 

Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm)
2 to 60 5 12 0.40 (10.1) 67 (99) 8.0 (20.2) 4.0 (10.1)
62 to 72 6 12 0.43 (10.8) 74 (110) 8.6 (21.7) 4.3 (10.9)
74 to 84 7 12 0.47 (12.0) 90 (134) 9.5 (24.0) 4.8 (12.0)
86 to 96 8 12 0.50 (12.8) 103 (153) 10.1 (25.6) 5.1 (12.8)
98 to 108 9 12 0.55 (13.9) 121 (180) 11.0 (27.8) 5.5 (13.9)
110 to 120 10 12 0.57 (14.5) 132 (196) 11.4 (29.0) 5.7 (14.5)
122 to 132 11 12 0.60 (15.4) 149 (221) 12.1 (30.8) 6.1 (15.4)
134 to 144 12 12 0.64 (16.3) 168 (250) 12.9 (33.0) 6.5 (16.4)
  • Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.