CampusLink™ LT Plenum Dry Single Jacket

Sample

CampusLink LTTM Loose tube | indoor-outdoor plenum | dry buffer tubes | dielectric (single jacket) with aluminum interlock armor 12-62.5/125 multimode fibers per buffer tube | 48 fibers total (printed in feet)

 

 

F DPLDB AJ 12 G6 048 M2
1 - Length Markings 2 - Product  Family 3 - Construction 4 - Fiber Grouping 5 - Fiber Type 6 - Fiber Count 7 - Fiber Grade

 

Choose from a range of single-mode and multi-mode connector options, or order pigtails. You can also specify fiber count (01-96), cable assembly length (001-999), and more.

Request a Quote Submit RFQ for Quantity Discounts or Customizations
Length (ft.):
Part Number

CampusLink LT Single Jacket  Dry Plenum is for use in indoor-outdoor cables. This cable is Dielectric and DPLDB series, OFNP/FT6. The OFNP rating is an identifier that shows this is optical fiber, nonconductive, plenum. The fiber count for this cable is 2 to 144.

See Corning Cross Reference table below.

PART NUMBER CONSTRUCTION for PLENUM DRY SINGLE JACKET FIBER OPTIC CABLE

 

1. Length Markings

F = feet

M = meters

 

2. Product Family

Riser/FT6 ⎸Dry Tubes ⎸OFNP/FT6

  • DPLDB = Indoor-Outdoor Plenum, All-Dielectric (single jacket) 2 to 144

 

3. Construction

(blank) = none

AJ = Jacketed aluminum (use with DRLDB and DPLDB)

SJ = Jacketed steel (use with DRLDB and DPLDB)

 

4. Fiber Grouping

12 = 12f per unit or tube


 

FIBER INFORMATION

 

5. Fiber Type

Single-Mode

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

 

Multi-Mode

Wavelength (nm)

Bandwidth (MHz)

1 GbE Dist

(m)

10 GbE Dist (m)

G6 = OM1 (62.5μm)

850/1300

200/500

300/550

33/___

G5 = OM2+ BIF (50μm)

850/1300

700/500

800

150/___

G3 = OM3 BIF (50μm)

850/1300

1500/500

1000

300/___

G4 = OM4 BIF (50μm)

850/1300

3500/500

1100

550/___


 

6. Fiber Count

002 to 288 fibers

For full specs on per fiber count, see fiber optic cable spec table below

 

7. Fiber Grade

 

Single-Mode

Attenuation (dB/km)

Wavelength (nm)

Fiber Type

E1 = 0.40/0.40/0.30

1310/1383/1550

HB, ES, or CE

E3 = 0.35/0.35/0.25

1310/1383/1550

HB, ES, B1, B2 or CE
 

 

Multi-Mode

Attenuation (dB/km)

Wavelength (nm)

M2 = 3.5/1.0

850/1300

M3 = 3.0/1.0

850/1300


 

Temperature Range

  • Shipping and Storage: Plenum -40°F to +158°F (-40°C to +70°C)
  • Installation: Plenum +32°F to +140°F (0°C to +60°C)
  • Operation: Plenum -40°F to +158°F (-40°C to +70°C)
  • Mechanical Specifications:
    • Maximum installation load: 600 lbf (2670 N)
    • Maximum operation load: 180 lbf (801 N)

 

See table below for Corning Cross References to Prysmian/Draka Parts

 

  Flame/Smoke Ratings        
Jacket Style Prysmian/Draka Corning Fiber Count Prysmian/Draka Part Number Corning Part Number
           
LT Single Jacket PVDF OFNP / FT6 OFNP / FT6 12 DPLDB-12-HB-012-E3 012EWP-T4101D20
LT Single Jacket PVDF OFNP / FT6 OFNP / FT6 24 DPLDB-12-HB-024-E3 024EWP-T4101D20
LT Single Jacket PVDF OFNP / FT6 OFNP / FT6 48 DPLDB-12-HB-048-E3 048EWP-T4101D20
LT Single Jacket PVDF OFNP / FT6 OFNP / FT6 72 DPLDB-12-HB-072-E3 072EWP-T4101D20
LT Single Jacket PVDF OFNP / FT6 OFNP / FT6 144 DPLDB-12-HB-144-E3 144EWP-T4101D20

 

Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm)
2 to 60 5 12 0.37 (9.3) 55 (82) 7.4 (18.8) 3.7 (9.4)
62 to 72 6 12 0.40 (10.2) 67 (99) 8.0 (20.4) 4.0 (10.2)
74 to 84 7 12 0.44 (11.1) 80 (119) 8.8 (22.4) 4.4 (11.2)
86 to 96 8 12 0.48 (12.2) 97 (145) 9.6 (24.4) 4.8 (12.2)
98 to 144 12/6 12 0.61 (15.6) 138 (206) 12.2 (31.0) 6.1 (15.5)

 

  • The compression rating for counts of 60 and below is 100N/cm.
  • Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.