Choose from a range of single-mode and multi-mode connector options, or order pigtails. You can also specify fiber count (01-96), cable assembly length (001-999), and more.
AIRGUARD® XP dielectric, double jacket, XPRLTM Series is for heavy duty, harsh environment applications. It is OFNG-LS/FT4 ST1 rated. The OFNG rating is an identifier that shows this is optical fiber, nonconductive, general use. It is available in 2 to 288 fiber count.
PART NUMBER CONSTRUCTION for XPRLTM SERIES FIBER OPTIC CABLE
1. Length Markings
2. Product Family
Dielectric (Double Jacket) XPRLTM Series | OFNG-LS/FT4 ST1
|
|
3. Construction
(blank) = Not available with interlock armor
|
4. Fiber Grouping
12 = 12f per unit or tube
|
FIBER INFORMATION
5. Fiber Type
Single-Mode
|
HB = Single-Mode (ITU G.652 C & D) Low Water Peak
|
ES = Draka™ Enhanced Single-Mode (ITU G.652 C & D)
|
CE = Corning™ SMF28e+ Single-Mode
|
B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)
|
B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)
|
Multi-Mode
|
Wavelength (nm)
|
Bandwidth (MHz)
|
1 GbE Dist
(m)
|
10 GbE Dist (m)
|
G6 = OM1 (62.5μm)
|
850/1300
|
200/500
|
300/550
|
33/___
|
G5 = OM2+ BIF (50μm)
|
850/1300
|
700/500
|
800
|
150/___
|
G3 = OM3 BIF (50μm)
|
850/1300
|
1500/500
|
1000
|
300/___
|
G4 = OM4 BIF (50μm)
|
850/1300
|
3500/500
|
1100
|
550/___
|
6. Fiber Count
For full specs on per fiber count, see fiber optic cable spec table below
7. Fiber Grade
Single-Mode
Attenuation (dB/km)
|
Wavelength (nm)
|
Fiber Type
|
E1 = 0.40/0.40/0.30
|
1310/1383/1550
|
HB, ES, or CE
|
E3 = 0.35/0.35/0.25
|
1310/1383/1550
|
HB, ES, B1, B2 or CE
|
Multi-Mode
Attenuation (dB/km)
|
Wavelength (nm)
|
Fiber Type
|
M2 = 3.5/1.0
|
850/1300
|
OM1 (62.5μm)
|
M3 = 3.0/1.0
|
850/1300
|
OM2+, OM3, OM4 (50μm)
|
Temperature Range
- Shipping and Storage: -58°F to +158°F (-50°C to +70°C)
- Installation: -22°F to +140°F (-30°C to +60°C)
- Operation: -58°F to +158°F (-50°C to +70°C)
Mechanical Specifications:
- Maximum Installation Load: 1000 lbf (4500 N)
- Maximum Operation Load: 300 lbf (1335 N)
- Crush Resistance: 4500 N
- Impact Force Resistance: 11.8 N*M
- Cold Impact Load: 5.88 N*M at -22°F (-30°C)
Fiber Count
|
# Buffer Tubes Outer/Inner Layer
|
Fibers per Unit or # of Units
|
Diameter Inches (mm)
|
Cable Weight lb/kft (kg/km)
|
Bend Radius Load Inches (cm)
|
Bend Radius No Load Inches (cm)
|
2 to 72
|
5
|
12
|
0.60 (15.3)
|
159 (237)
|
12.0 (30.5)
|
6.0 (15.3)
|
74 to 84
|
7
|
12
|
0.64 (16.2)
|
176 (262)
|
12.8 (32.6)
|
6.4 (16.3)
|
86 to 96
|
8
|
12
|
0.67 (17.1)
|
198 (294)
|
13.4 (34.1)
|
6.7 (17.1)
|
98 to 108
|
9
|
12
|
0.72 (18.2)
|
216 (322)
|
14.2 (36.1)
|
7.1 (18.1)
|
110 to 120
|
10
|
12
|
0.74 (18.8)
|
238 (354)
|
14.8 (37.6)
|
7.4 (18.4)
|
122 to 132
|
11
|
12
|
0.78 (19.7)
|
260 (387)
|
15.6 (39.7)
|
7.8 (19.9)
|
134 to 144
|
12
|
12
|
0.83 (21.0)
|
294 (438)
|
16.6 (42.2)
|
8.3 (21.1)
|
146 to 216
|
12/6
|
12
|
0.81 (20.5)
|
267 (398)
|
16.2 (41.2)
|
8.1 (20.6)
|
218 to 264
|
14/8
|
12
|
0.90 (22.8)
|
333 (496)
|
18.0 (45.8)
|
9.0 (22.9)
|
266 to 288
|
15/9
|
12
|
0.94 (24.0)
|
358 (532)
|
18.6 (47.3)
|
9.3 (23.7)
|