AIRGUARD® XP Dielectric (Single Jacket) XPRLTMB Series

Sample

Indoor/Outdoor Loose Tube | AIRGUARD® Series, Dielectric (single Jacket) | General Purpose rated | 12 fibers per buffer tube 48 62.5/125 multimode fibers total (printed in feet)

 

F XPRLTMB Blank 12 G6 048 M2
1 - Length Markings 2 - Product  Family 3 - Construction 4 - Fiber Grouping 5 - Fiber Type 6 - Fiber Count 7 - Fiber Grade

 

Choose from a range of single-mode and multi-mode connector options, or order pigtails. You can also specify fiber count (01-96), cable assembly length (001-999), and more.

Request a Quote Submit RFQ for Quantity Discounts or Customizations
Length (ft.):
Part Number

AIRGUARD® XP dielectric, single jacket, XPRLTMB Series is for heavy duty, harsh environment applications. It is OFN rated. The OFN rating is an identifier that shows this is optical fiber, nonconductive. It is available in 2 to 216 fiber count.

 

PART NUMBER CONSTRUCTION for XPRLTMB SERIES FIBER OPTIC CABLE

 

1. Length Markings

F = feet

M = meters

 

2. Product Family

Dielectric (Single Jacket) XPRLTMB Series | OFN

  • XPRLTMB = AIRGUARD® XP (single jacket) 2 to 216

 

3. Construction

(blank) = Not available with interlock armor

 

4. Fiber Grouping

12 = 12f per unit or tube


 

FIBER INFORMATION

 

5. Fiber Type
 

Single-Mode

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Draka™ Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)


 

Multi-Mode

Wavelength (nm)

Bandwidth (MHz)

1 GbE Dist

(m)

10 GbE Dist (m)

G6 = OM1 (62.5μm)

850/1300

200/500

300/550

33/___

G5 = OM2+ BIF (50μm)

850/1300

700/500

800

150/___

G3 = OM3 BIF (50μm)

850/1300

1500/500

1000

300/___

G4 = OM4 BIF (50μm)

850/1300

3500/500

1100

550/___


 

6. Fiber Count

002 to 216 fibers

For full specs on per fiber count, see fiber optic cable spec table below
 

7. Fiber Grade

 

Single-Mode

Attenuation (dB/km)

Wavelength (nm)

Fiber Type

E1 = 0.40/0.40/0.30

1310/1383/1550

HB, ES, or CE

E3 = 0.35/0.35/0.25

1310/1383/1550

HB, ES, B1, B2 or CE

 

Multi-Mode

Attenuation (dB/km)

Wavelength (nm)

Fiber Type

M2 = 3.5/1.0

850/1300

OM1 (62.5μm)

M3 = 3.0/1.0

850/1300

OM2+, OM3, OM4 (50μm)

 

Temperature Range:

  • Shipping and Storage: -40°F to +176°F (-40°C to +80°C)

  • Installation: +14°F to +140°F (-10°C to +60°C)

  • Operation: -40°F to +176°F (-40°C to +80°C)

Mechanical Specifications: 

  • Maximum Installation Load: 600 lbf (2670 N)

  • Maximum Operation Load: 180 lbf (801 N)

  • Cold Impact Load: 5.88 N*M at -22°F (-30°C)

 

 

Fiber Count

# Buffer Tubes Outer/Inner Layer

Fibers per Unit or # of Units

Diameter Inches (mm)

Cable Weight lb/kft (kg/km)

Bend Radius Load Inches (cm)

Bend Radius No Load Inches (cm)

2 to 60

5

12

0.41 (10.3)

62 (93)

8.2 (20.9)

4.1 (10.5)

62 to 72

6

12

0.44 (11.2)

73 (109)

8.8 (22.4)

4.4 (11.2)

74 to 84

7

12

0.47 (11.9)

83 (123)

9.4 (23.9)

4.7 (12.0)

86 to 96

8

12

0.51 (12.9)

95 (142)

10.2 (25.9)

5.1 (13.0)

98 to 108

9

12

0.55 (13.9)

111 (165)

11.0 (28.0)

5.5 (14.0)

110 to 120

10

12

0.58 (14.8)

125 (186

11.6 (29.5)

5.8 (14.8)

122 to 132

11

12

0.62 (15.7)

140 (209)

12.4 (31.5)

6.2 (15.8)

134 to 216

12/6

12

0.65 (16.5)

154 (229)

13.0 (33.0)

6.5 (16.6)

 

  • Cable damage my occur if installation temperature limits are exceeded; therefore, Prysmian Group recommends storing I/O cables in appropriate termperature conditions ≥ 24hours prior to placement.