ezINTERLOCK™ Indoor/Outdoor Dry Fiber Plenum Cable

ezINTERLOCK Indoor/Outdoor Dry Plenum Fiber Optic Cable Assemblies

exINTERLOCKTM Loose tube fiber optic cable is ideal for all data center cabling needs. These cables contain 12 units of fiber which can be combined in an MTP cable saving crucial rack space. You can select from both single-mode fiber cable or multi-mode fiber cable depending on your application needs. If you are looking for a better option, these cables can be used to replace riser cable in all applications but riser cable cannot replace fiber plenum cables in any application.

F DPLDBAJ AJ 12 G6 048 M2
1 - Length Markings 2 - Product  Family 3 - Construction 4 - Fiber Grouping 5 - Fiber Type 6 - Fiber Count 7 - Fiber Grade

 

Choose from a range of single-mode and multi-mode connector options, or order pigtails. You can also specify fiber count (01-96), cable assembly length (001-999), and more.

Request a Quote Submit RFQ for Quantity Discounts or Customizations
Length (ft.):
Part Number

ezINTERLOCK Indoor/Outdoor Dry Plenum Fiber Optic cable is for use in indoor-outdoor applications. This cable is DPLDBAJ series, OFCP/FT6. The OFCP rating is an identifier that shows this is optical fiber, conductive, plenum. The fiber count for this cable is 2 to 144.

 

See Corning Cross Reference table below.

 

PART NUMBER CONSTRUCTION for DRY PLENUM FIBER OPTIC CABLE

 

1. Length Markings

F = feet

M = meters

 

2. Product Family

ezINTERLOCK Dry Tube | Plenum | OFCP/FT6 (2 to 144 fibers)

  • DPLDBAJ = ezINTERLOCK I/O LT Dry Plenum with Aluminum Interlock Armor

 

3. Construction

AJ = Jacketed Aluminum

SJ = Jacketed Steel

 

4. Fiber Grouping

12 = 12f per unit or tube


 

FIBER INFORMATION

 

5. Fiber Type

Single-Mode

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

 

Multi-Mode

Wavelength (nm)

Bandwidth (MHz)

1 GbE Dist

(m)

10 GbE Dist (m)

G6 = OM1 (62.5μm)

850/1300

200/500

300/550

33/___

G5 = OM2+ BIF (50μm)

850/1300

700/500

800

150/___

G3 = OM3 BIF (50μm)

850/1300

1500/500

1000

300/___

G4 = OM4 BIF (50μm)

850/1300

3500/500

1100

550/___


 

6. Fiber Count

002 to 288 fibers (gel-filled designs only up to 144f)

For full specs on per fiber count, see fiber optic cable spec table below

 

7. Fiber Grade

 

Single-Mode

Attenuation (dB/km)

Wavelength (nm)

Fiber Type

E1 = 0.40/0.40/0.30

1310/1383/1550

HB, ES, or CE

E3 = 0.35/0.35/0.25

1310/1383/1550

HB, ES, B1, B2 or CE

 

Multi-Mode

Attenuation (dB/km)

Wavelength (nm)

M2 = 3.5/1.0

850/1300

M3 = 3.0/1.0

850/1300

 

 

Temperature Range

  • Shipping and Storage: Plenum -40° F to +158° F (-40° C to +70° C)
  • Installation: Plenum +32° F to +140° F (0° C to +60° C)
  • Operation: Plenum -40° F to +158° F (-40° C to +70° C)
  • Mechanical Specifications:
    • Maximum installation load: 600 lbf (2670 N)
    • Maximum operation load: 180 lbf (801 N)

Outer Jacket Colors

  • Orange: Multimode OM1 and OM2+
  • Aqua: Multimode OM3 and OM4
  • Yellow: Single-mode
  • Black: Hybrid

 

See table below for Corning Cross References to Prysmian/Draka Parts

 

  Flame/Smoke Ratings        
Jacket Style Prysmian/Draka Corning Fiber Count Prysmian/Draka Part Number Corning Part Number
           
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 12 DPLDBAJ-12-HB-012-E3 012EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 24 DPLDBAJ-12-HB-024-E3 024EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 48 DPLDBAJ-12-HB-048-E3 048EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 72 DPLDBAJ-12-HB-072-E3 072EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 NA 144 DPLDBAJ-12-HB-144-E3 NA

 

 

Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm)
2 to 60 5 12 0.65 (16.4) 147 (219) 12.9 (32.8) 7.3 (18.5)
62 to 72 6 12 0.68 (17.3) 166 (247) 13.6 (34.6) 7.6 (19.2)
74 to 84 7 12 0.72 (18.2) 188 (279) 14.4 (36.4) 8.1 (20.4)
86 to 96 8 12 0.76 (19.3) 214 (319) 15.2 (38.6) 8.4 (21.2)
98 to 144 12/6 12 0.89 (22.7) 320 (476) 17.9 (45.4) 9.8 (24.8)

 

  • Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.