add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

ezINTERLOCK™ Indoor/Outdoor Dry Plenum

More ezINTERLOCK™ Indoor/Outdoor Riser & Plenum Options

 

Sample

exINTERLOCKTM Loose tube | indoor-outdoor plenum | dry buffer tubes | with jacketed aluminum interlock armor 12-62.5/125 multimode fibers per buffer tube | 48 fibers total (printed in feet)

 

 

F DPLDBAJ AJ 12 G6 048 M2
1 - Length Markings 2 - Product  Family 3 - Construction 4 - Fiber Grouping 5 - Fiber Type 6 - Fiber Count 7 - Fiber Grade

 

Choose from a range of single-mode and multi-mode connector options, or order pigtails. You can also specify fiber count (01-96), cable assembly length (001-999), and more.

Request a Quote Submit RFQ for Quantity Discounts or Customizations
Length (ft.):
Part Number

ezINTERLOCK Indoor/Outdoor Dry Plenum is for use in indoor-outdoor applications. This cable is DPLDBAJ series, OFCP/FT6. The OFCP rating is an identifier that shows this is optical fiber, conductive, plenum. The fiber count for this cable is 2 to 144.

 

See Corning Cross Reference table below.

 

PART NUMBER CONSTRUCTION for DRY PLENUM FIBER OPTIC CABLE

 

1. Length Markings

F = feet

M = meters

 

2. Product Family

ezINTERLOCK Dry Tube | Plenum | OFCP/FT6 (2 to 144 fibers)

  • DPLDBAJ = ezINTERLOCK I/O LT Dry Plenum with Aluminum Interlock Armor

 

3. Construction

AJ = Jacketed Aluminum

SJ = Jacketed Steel

 

4. Fiber Grouping

12 = 12f per unit or tube


 

FIBER INFORMATION

 

5. Fiber Type

Single-Mode

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

 

Multi-Mode

Wavelength (nm)

Bandwidth (MHz)

1 GbE Dist

(m)

10 GbE Dist (m)

G6 = OM1 (62.5μm)

850/1300

200/500

300/550

33/___

G5 = OM2+ BIF (50μm)

850/1300

700/500

800

150/___

G3 = OM3 BIF (50μm)

850/1300

1500/500

1000

300/___

G4 = OM4 BIF (50μm)

850/1300

3500/500

1100

550/___


 

6. Fiber Count

002 to 288 fibers (gel-filled designs only up to 144f)

For full specs on per fiber count, see fiber optic cable spec table below

 

7. Fiber Grade

 

Single-Mode

Attenuation (dB/km)

Wavelength (nm)

Fiber Type

E1 = 0.40/0.40/0.30

1310/1383/1550

HB, ES, or CE

E3 = 0.35/0.35/0.25

1310/1383/1550

HB, ES, B1, B2 or CE

 

Multi-Mode

Attenuation (dB/km)

Wavelength (nm)

M2 = 3.5/1.0

850/1300

M3 = 3.0/1.0

850/1300

 

 

Temperature Range

  • Shipping and Storage: Plenum -40° F to +158° F (-40° C to +70° C)
  • Installation: Plenum +32° F to +140° F (0° C to +60° C)
  • Operation: Plenum -40° F to +158° F (-40° C to +70° C)
  • Mechanical Specifications:
    • Maximum installation load: 600 lbf (2670 N)
    • Maximum operation load: 180 lbf (801 N)

Outer Jacket Colors

  • Orange: Multimode OM1 and OM2+
  • Aqua: Multimode OM3 and OM4
  • Yellow: Single-mode
  • Black: Hybrid

 

See table below for Corning Cross References to Prysmian/Draka Parts

 

  Flame/Smoke Ratings        
Jacket Style Prysmian/Draka Corning Fiber Count Prysmian/Draka Part Number Corning Part Number
           
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 12 DPLDBAJ-12-HB-012-E3 012EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 24 DPLDBAJ-12-HB-024-E3 024EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 48 DPLDBAJ-12-HB-048-E3 048EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 OFCP / FT6 72 DPLDBAJ-12-HB-072-E3 072EWP-T4101DA3
LT Interlocking Armor/Plenum OFCP / FT6 NA 144 DPLDBAJ-12-HB-144-E3 NA

 

 

Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm)
2 to 60 5 12 0.65 (16.4) 147 (219) 12.9 (32.8) 7.3 (18.5)
62 to 72 6 12 0.68 (17.3) 166 (247) 13.6 (34.6) 7.6 (19.2)
74 to 84 7 12 0.72 (18.2) 188 (279) 14.4 (36.4) 8.1 (20.4)
86 to 96 8 12 0.76 (19.3) 214 (319) 15.2 (38.6) 8.4 (21.2)
98 to 144 12/6 12 0.89 (22.7) 320 (476) 17.9 (45.4) 9.8 (24.8)

 

  • Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.