1614 Specifications: (subject to change without notice) |
AWG Size |
28 |
No. of Pairs |
5 |
Conductor Stranding |
7/36 |
No. of Strands |
7 |
Strand Size |
36 |
Nom. Insul. Thick. (in) |
0.009 |
Jacket Thick |
0.032 |
Nom. O.D. of Cable (in) |
0.226 |
Nom. DCR of Cond. |
67.5 |
Nom. DCR of Shld. |
3.5 |
Nom. Cap. (C-C) |
14.0 |
Nom. Cap. (C-SC) |
23.5 |
Vel. of Prop. |
66 |
Nom. Imp. |
100 |
Color Code Chart |
3 |
UL Style |
2960 |
NEC Type |
CL2 |
Cond. Material |
Tinned Copper |
Insul. Material |
Lo-Capacitance Polyethylene (PE) |
Jacket Material |
Polyvinylchloride (PVC) |
Shield |
Overall Braid and Foil Shield |
Shield Material |
Tinned Copper Braid and Aluminum/Polyester Foil |
Shield Coverage |
90% Braid; 100%, with 25% overlap, foil facing out |
Min. Temp |
-20°C |
Max. Temp |
75°C |
Drain Wire |
Stranded Tinned Copper Drain Wire |
Voltage |
30 |