Our Multi-Conductor Type W Cable is ideal for use in light to medium-duty mining applications. This cable has excellent impact resistance and has a core bound for superior flexibility and toughness. It withstands exposure to oil, acids, alkalies, heat, moisture, and most chemicals. This cable is also indent-printed for easy identification.

39 items

  • W-1-2C
    $0.00 / 1000 FT
    • Amps: 202
    • Approx LBS/MFT: 1490.00
    • AWG Size: 1
    View Details
  • W-1-3C
    $0.00 / 1000 FT
    • Amps: 202
    • Approx LBS/MFT: 1600.00
    • AWG Size: 1
    View Details
  • W-1-4C
    $0.00 / 1000 FT
    • Amps: 177
    • Approx LBS/MFT: 2450.00
    • AWG Size: 1
    Order
    Add to List
  • W-1-5C
    $0.00 / 1000 FT
    • Amps: 141
    • Approx LBS/MFT: 3040.00
    • AWG Size: 1
    View Details
  • W-1/0-2C
    $0.00 / 1000 FT
    • Amps: 234
    • Approx LBS/MFT: 1710.00
    • AWG Size: 1/0
    View Details
  • W-1/0-3C
    $0.00 / 1000 FT
    • Amps: 234
    • Approx LBS/MFT: 2280.00
    • AWG Size: 1/0
    View Details
  • W-1/0-4C
    $0.00 / 1000 FT
    • Amps: 205
    • Approx LBS/MFT: 2570.00
    • AWG Size: 1/0
    View Details
  • W-1/0-5C
    $0.00 / 1000 FT
    • Amps: 164
    • Approx LBS/MFT: 3460.00
    • AWG Size: 1/0
    View Details

Multi-Conductor Type W Cable Specifications

Multi-Conductor Type W Construction:

  • Conductors: 8 AWG through 500 MCM fully annealed bunch stranded bare copper
  • Insulation: Premium-grade, color-coded 90°C EPDM
    • Color Code Chart for Type W Portable Power Cable
       
      No. of Cond. Color Code
      2 Black, White
      3 Black, White, Green
      4 Black, White, Red, Green
      5 Black, White, Red, Green, Orange

  • Jacket: CPE , Black

Multi-Conductor Type W Ratings and Approvals:

  • CSA
  • MSHA Approved
  • UL Type W
  • RoHS Compliant
  • Temperature Range: -40°C to +90°C
  • Voltage Rating: 2000V

Multi-Conductor Type W Applications:

  • Heavy-duty service as power supply cable
  • AC systems (grounded and ungrounded)
  • Mobile and portable electrical equipment
  • Motor and battery leads
  • 2-conductor cables-use on DC or AC single-phase systems where grounding is not required
  • 3-conductor cables-use on AC systems where no grounding is required, or on DC systems with one conductor for grounding
  • 4-conductor cables-use on two- or three phase AC systems with one conductor used for grounding
  • 5-conductor cables-use in applications where separating the system neutral from the frame ground is required