Jacketed Aluminum Duplex Conductor Underground Power Cable

Part Number Phase Cond. - AWG SizePhase Cond.- Cond. Strand. Phase Cond. - Nom. Insul. Thick. (in)Phase Cond. - Jacket Thick. (in)Neutral Cond. - AWG Size Neutral Cond. - Cond. Strand.Neutral Cond. - Nom. Insul. Thick. (in)Neutral Cond - Jacket Thick. (in)Nom. EFF O.D. (in)Approx LBS/MFTAmpacity (Direct Burial)Ampacity (Duct in Air)
Delgado/AR/EYS 4 7 0.030 0.030 4 7 0.030 0.030 0.70 133 145 85
Everett/AR/EYS 2 7 0.030 0.030 2 7 0.030 0.030 0.82 191 185 110
Findlay/AR/EYS 2/0 19 0.040 0.040 2/0 19 0.040 0.040 1.14 368 270 170
Hanover/AR/EYS 4/0 19 0.040 0.040 4/0 19 0.040 0.040 1.36 543 350 225
Jacketed Aluminum Duplex Conductor Underground Power Cable
600V XLPE Insulation

Jacketed Aluminum Duplex Conductor Underground Power Cable Construction:

  • Complete Cable:
    • One phase conductor, and one neutral conductor are insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
    • Twisted cables form duplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation & Jacket:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
    • The phase conductor is black, and the neutral conductor is black identified by three extruded yellow stripes.

Jacketed Aluminum Duplex Conductor Underground Power Cable Features and Benefits:

  • Insulation/Jacket system provide high degree of protection against insulation damage
  • For NEC-complying applications, the maximum conductor operating temp is 90°C in wet or dry locations
  • Also suitable for non-code-complying installations with a temperature of 90°C in wet or dry locations in accordance with ICEA specifications

Jacketed Aluminum Duplex Conductor Underground Power Cable Applications:

  • Intended for use in underground systems operated at 600 volts or less.

Jacketed Aluminum Duplex Conductor Underground Power Cable Options:

  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • CDC Combined Duct & Cable
  • Reeless Package
  • PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
  • Type USE-2 per UL 44