EPR/AIA/PVC Unshielded Armored Power Cable (2400 V)

Part Number AWG SizeGround AWG SizeNo. of Cond.Nom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)Nom. Dia. of Cond.Armor (in)Approx LBS/MFT
87355.290300-18 6 6 3 0.115 0.050 1.27 0.17 1.16 854
87355.290200-18 4 6 3 0.115 0.050 1.37 0.21 1.26 1056
87355.290100-18 2 6 3 0.115 0.050 1.48 0.27 1.37 1363
87355.292550-18 1/0 4 3 0.115 0.060 1.74 0.34 1.61 2003
87355.292600-18 2/0 4 3 0.115 0.060 1.84 0.38 1.71 2326
87355.292700-18 4/0 3 3 0.115 0.060 2.05 0.48 1.92 3256
87355.293000-18 250 3 3 0.115 0.060 2.13 0.52 2.00 3689
87355.293100-18 350 2 3 0.115 0.060 2.34 0.62 2.21 4825
87355.293250-18 500 1 3 0.115 0.075 2.63 0.74 2.46 6567
87355.293500-18 750 1/0 3 0.115 0.075 3.00 0.91 2.83 9320
87355.293750-18 1000 1/0 3 0.115 0.085 3.35 1.07 3.16 12023

EPR/AIA/PVC Unshielded Armored Power Cable (2400 V)
UL Type MV-90 or MC, Three Conductor, 2400 V

EPR/AIA/PVC Unshielded Armored Power Cable Approvals:

  • National Electric Code (NEC)
  • ICEA S-95-658/NEMA WC 70
  • UL Listed as Type MV or Type MC
  • UL 1072
  • UL 1569
  • IEEE 1202 (70,000 BTU/hr)
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • ICEA T-29-520 (210,000 BTU/hr)
  • ICEA T-30-520 (70,000 BTU/hr)
  • Meets EPA 40 CFR part 261 leachable lead content per TCLP method
  • OSHA acceptable

EPR/AIA/PVC Unshielded Armored Power Cable Construction:

  • Conductor:
    • 6 AWG thru 1000 kcmil bare copper, compact Class B strand
  • Extended Strand Shield (ESS):
    • Extruded Thermoset Semi-Conductng Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) colored to contrast with black conducting shield layer
  • Ground:
    • Annealed bare copper Class B stranding per ASTM B8
  • Armor:
    • Aluminum Interlocked Armor (AIA)
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) - yellow

EPR/AIA/PVC Unshielded Armored Power Cable Options:

  • Other constructions available upon request

EPR/AIA/PVC Unshielded Armored Power Cable Applications:

  • Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is the major concern, where maximum performance is demanded, space is limited, ease of installation is critical and fire resistance is necessary
  • May be installed in wet or dry locations, indoors or outdoors and in exposed or concealed work
  • May be used in cable trays or on approved supports in protected areas
  • Permitted for use in Class I Division 2, Class II Division 2, and Class III Division 1 and 2 per NEC Article 334

EPR/AIA/PVC Unshielded Armored Power Cable Features:

  • Rated at 90°C wet or dry
  • Excellent heat and moisture resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical and radiation resistant
  • Excellent crush resistance
  • Flame or sunlight resistance
  • Cost-effective alternative to installations in conduit
  • Meets cold bend test at -25°C