EPR Power Cable with Overall CPE Jacket and Copper Tape Shield (15kV)

Part Number AWG SizeGround AWG SizeJacket ThickNom. O.D. (in)Nom. Dia. of Cond.Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFTAmpacity (Duct in Air)Ampacity (Underground)Ampacity (Direct Burial)
77965.220100-18 2 6 0.110 2.0400 0.27 0.710 0.800 2226 165 160 185
77965.222550-18 1/0 4 0.110 2.2000 0.34 0.780 0.865 2811 215 210 240
77965.222600-18 2/0 4 0.110 2.3000 0.38 0.820 0.905 3163 245 235 275
77965.222700-18 4/0 3 0.110 2.5200 0.48 0.920 1.005 4203 320 305 360
77965.223000-18 250 2 0.110 2.6600 0.53 0.970 1.060 4775 350 335 400
77965.223100-18 350 2 0.110 2.9400 0.62 1.070 1.155 6182 430 400 490
77965.223250-18 500 1 0.140 3021 0.74 1.190 1.275 7686 525 485 600
77965.223500-18 750 1/0 0.140 3.61 0.91 1.370 1.460 10978 635 585 745
77965.223750-18 1000 2/0 0.140 3.99 1.06 1.520 1.610 13938 725 660 860

EPR Power Cable with Overall CPE Jacket and Copper Tape Shield (15kV)
UL Type MV-105, 133% Ins. Level, 220 Mils, Three Conductor, 15kV

Product Approvals:

  • Industry Approvals:
    • National Electric Code (NEC)
    • UL 1072
    • ICEA S-93-639/NEMA WC74
    • ICEA S-97-682
    • AEIC CS8
    • UL Listed as Type MV-105 for use in accordance with NEC
    • UL 1685 (70,000 BTU/hr)
    • OSHA acceptable
  • Optional Flame Tests:
    • IEEE 1202 (70,000 BTU/hr)/CSA FT4
    • ICEA T-29-520 (210,000 BTU/hr)

EPR Power Cable with Overall CPE Jacket and Copper Tape Shield (15kV) Construction:

  • Conductor:
    • 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand
  • Extended Strand Shield (ESS):
    • Extruded Thermoset Semi-Conducting Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers
  • Extruded Insulation Shield (EIS):
      Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • Metallic Shield:
    • 5 mil annealed copper tape with an overlap of 25%.
  • Grounding Conductor:
    • 1 bare grounding conductor may be in contact with metallic shielding tape
  • Overall Jacket:
    • Flame retardant, moisture and sunlight resistant Chlorinated Polyethylene (CPE)

EPR Power Cable with Overall CPE Jacket and Copper Tape Shield (15kV) Options:

  • PVC jacket
  • Low-Smoke, Zero-Halogen (LSZH) jacket
  • Jacketed singles
  • UniShield® singles
  • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-0-610
  • 3 bare copper ground wires
  • Covered ground wires

EPR Power Cable with Overall CPE Jacket and Copper Tape Shield (15kV) Applications:

  • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical
  • Suitable for use in wet or dry locations, when installed in accordance with NEC
  • For use in aerial, direct burial, conduit, open tray and underground duct installations
  • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5)

EPR Power Cable with Overall CPE Jacket and Copper Tape Shield (15kV) Features:

  • Rated at 105°C
  • Excellent heat and moisture resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical resistant
  • Meets cold bend test at -35°C