EPR Power Cable with Overall PVC Jacket and Copper Tape Shield (25kV and 35kV)

Part Number AWG SizeGround AWG SizeJacket ThickNom. O.D. (in)Nom. Dia. of Cond.Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFTAmpacity (Duct in Air)Ampacity (Underground)Ampacity (Direct Burial)
77465.242550-18 1/0 4 0.110 2.7300 0.34 1.020 1.115 3672 215 210 255
77465.242600-18 2/0 4 0.110 2.8100 0.38 1.060 1.160 4061 245 235 290
77465.242700-18 4/0 3 0.140 3.10 0.48 1.160 1.260 5313 320 305 375
77465.243000-18 250 2 0.140 3.21 0.53 1.210 1.315 6214 350 335 410
77465.243100-18 350 2 0.140 3.42 0.62 1.310 1.410 7138 430 400 495
77465.243250-18 500 1 0.140 3.68 0.74 1.430 1.530 9012 525 485 590
77465.243500-18 750 1/0 0.140 4.10 0.91 1.610 1.710 12030 635 585 720

EPR Power Cable with Overall PVC Jacket and Copper Tape Shield (25kV and 35kV)
UL Type MV-105, 133% / 100% Ins. Levels, 345 Mils, 25kV and 35kV

Product Approvals:

  • Industry Approvals:
    • National Electric Code (NEC)
    • UL 1072
    • ICEA S-93-639/NEMA WC74
    • ICEA S-97-682
    • AEIC CS8
    • UL Listed as Type MV-105 for use in accordance with NEC
    • UL 1685 (70,000 BTU/hr)
    • Meeets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method
    • OSHA acceptable
  • Optional Flame Tests:
    • IEEE 1202 (70,000 BTU/hr)/CSA FT4
    • ICEA T-29-520 (210,000 BTU/hr)

EPR Power Cable with Overall PVC Jacket and Copper Tape Shield (25kV and 35kV) Construction:

  • Conductor:
    • 1/0 AWG thru 750 kcmil annealed bare copper compact Class B strand
  • Extended Strand Shield (ESS):
    • Extruded Thermoset Semi-Conducting Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers
  • Extruded Insulation Shield (EIS):
    • Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • Metallic Shield:
    • 5 mil annealed copper tape with an overlap of 25%
  • Grounding Conductor:
    • 1 bare grounding conductor may be in contact with metallic shielding tape
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)

EPR Power Cable with Overall PVC Jacket and Copper Tape Shield (25kV and 35kV) Options:

  • PVC jacket colors other than black
  • Flame Retardant, Chlorinated Polyethylene (CPE) jacket
  • Low-Smoke, Zero-Halogen (LSZH) jacket
  • Jacketed singles
  • UniShield® singles
  • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610
  • 3 bare copper ground wires
  • Covered ground wires
  • 25kV 100% Insulation Level
  • 35kV 133& Insulation Level

EPR Power Cable with Overall PVC Jacket and Copper Tape Shield (25kV and 35kV) Applications:

  • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical
  • Suitable for use in wet or dry locations, when installed in accordance with NEC
  • For use in aerial, direct burial, conduit, open tray and underground duct installations

EPR Power Cable with Overall PVC Jacket and Copper Tape Shield (25kV and 35kV) Features:

  • Rated at 105°C
  • Excellent heat and moisture resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical resistant
  • Meets cold bend test at -35°C