add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

EPR/PVC Power Cable with Copper Tape Shield (25kV and 35kV)

Part Number AWG SizeJacket ThickNom. O.D. (in)Nom. Dia. of Cond.Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFTAmpacity (Duct in Air)Ampacity (Underground)Ampacity (Direct Burial)
85305.067550-18 1/0 0.080 1.3100 0.34 1.020 1.115 1090 215 215 295
85305.067600-18 2/0 0.080 1.3500 0.38 1.060 1.160 1211 255 245 335
85305.067650-18 3/0 0.080 1.4000 0.43 1.105 1.205 1360 290 275 380
85305.067700-18 4/0 0.080 1.4500 0.48 1.160 1.260 1547 330 315 435
85305.068000-18 250 0.080 1.5100 0.53 1.210 1.315 1712 365 345 475
85305.068100-18 350 0.080 1.6000 0.62 1.310 1.410 2108 440 415 575
85305.068250-18 500 0.080 1.7800 0.74 1.430 1.530 2783 535 500 700
85305.068500-18 750 0.110 1.9600 0.91 1.610 1.710 3733 655 610 865
85305.068750-18 1000 0.110 2.1000 1.06 1.760 1.865 4651 755 690 1005

EPR/PVC Power Cable with Copper Tape Shield (25kV and 35kV)
UL Type MV-105, 133% / 100% Ins. Levels, 345 Mils, 25kV and 35kV

Product Approvals:

  • Industry Approvals
    • National Electric Code (NEC)
    • UL 1072
    • ICEA S-93-639/NEMA WC74
    • ICEA S-97-682
    • AEIC CS8
    • UL Listed as Type MV-105 for use in accordance with NEC
    • Sizes 1/0 AWG and larger are listed and marked "Sunlight-Resistant FOR CT USE" in accordance with NEC
    • IEEE 1202 (70,000 BTU/hr)/CSA FT4
    • Meeets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method
    • OSHA acceptable
  • Optional Flame Tests:
    • ICEA T-29-520 (210,000 BTU/hr)

EPR/PVC Power Cable with Copper Tape Shield (25kV and 35kV) Construction:

  • Conductor:
    • 1/0 AWG thru 1000 kcmil annealed bare copper compact Class B strand
  • Extended Strand Shield (ESS):
    • Extruded Thermoset Semi-Conducting Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers
  • Extruded Insulation Shield (EIS):
    • Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • Metallic Shield:
    • 5 mil annealed copper tape with an overlap of 25%
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)

EPR/PVC Power Cable with Copper Tape Shield (25kV and 35kV) Options:

  • PVC jacket colors other than black
  • Flame Retardant, Chlorinated Polyethylene (CPE) jacket
  • Low-Smoke, Zero-Halogen (LSZH) jacket
  • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610
  • 25kV 100% Insulation Level
  • 35kV 133& Insulation Level

EPR/PVC Power Cable with Copper Tape Shield (25kV and 35kV) Applications:

  • Superior performance in pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines, utility power generating stations and other industrial three-phase applications
  • Suitable for use in wet or dry locations, when installed in accordance with NEC
  • For use in aerial, direct burial, conduit, open tray and underground duct installations
  • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5)

EPR/PVC Power Cable with Copper Tape Shield (25kV and 35kV) Features:

  • Rated at 105°C
  • Excellent heat and moisture resistance
  • Excellent flame resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical resistant
  • Meets cold bend test at -35°C