EPR/PVC Power Cable with Copper Tape Shield (5kV and 8kV)

Part Number AWG SizeJacket ThickNom. O.D. (in)Nom. Dia. of Cond.Min. Insul. Dia. (in)Max. Insul. Dia. (in)Approx LBS/MFTAmpacity (Duct in Air)Ampacity (Underground)
85005.60300-18 6 0.060 0.6500 0.17 0.415 0.490 295 93 97
85005.60200-18 4 0.060 0.7000 0.22 0.455 0.535 365 120 125
85005.60100-18 2 0.060 0.7600 0.27 0.510 0.590 471 165 165
85005.60050-18 1 0.060 0.7900 0.31 0.545 0.620 539 190 185
85005.62550-18 1/0 0.060 0.8200 0.34 0.580 0.655 623 215 215
85005.62600-18 2/0 0.060 0.8600 0.38 0.620 0.695 728 255 245
85005.62650-18 3/0 0.080 0.9400 0.43 0.665 0.745 886 290 275
85005.67700-18 4/0 0.080 1.0000 0.48 0.720 0.795 1053 330 315
85005.68000-18 250 0.080 1.0500 0.53 0.770 0.850 1199 365 345
85005.68100-18 350 0.080 1.1400 0.62 0.870 0.945 1559 440 415
85005.68250-18 500 0.080 1.2700 0.74 0.990 1.065 2088 535 500
85005.68500-18 750 0.080 1.4500 0.91 1.170 1.250 2962 655 610
85005.68750-18 1000 0.080 1.6000 1.06 1.330 1.400 3815 755 690

EPR/PVC Power Cable with Copper Tape Shield (5kV and 8kV)
UL Type MV-105, 133% / 100% Ins. Levels, 115 Mils, 5kV and 8kV

Product Approvals:

  • Industry Approvals
    • National Electric Code (NEC)
    • UL 1072
    • ICEA S-93-639/NEMA WC71
    • ICEA S-97-682
    • AEIC CS8
    • UL Listed as Type MV-105 for use in accordance with NEC
    • Sizes 1/0 AWG and larger are listed and marked "Sunlight-Resistant FOR CT USE" in accordance with NEC and also meet IEEE 383 (70,000 BTU/hr)
    • IEEE 1202 (70,000 BTU/hr)/CSA FT4
    • Meets EPA 40 CFR part 261 leachable lead content per TCLP method
    • OSHA acceptable
  • Optional Flame Tests
    • ICEA T-29-520 (210,000 BTU/hr)

EPR/PVC Power Cable with Copper Tape Shield (5kV and 8kV) Construction:

  • Conductor:
    • 6 AWG thru 1000 kcmil annealed bare copper Class B strand
  • Extended Strand Shield (ESS):
    • Extruded Thermoset Semi-Conducting Stress Control Layer over conductor
  • Insulation:
    • Ethylene Propylene Rubber (EPR) colored to contrast with black jacket material
  • Extruded Insulation Shield (EIS)
    • Thermoset Semi-Conducting Polymeric Layer free stripping from insulation
  • Metallic Shield
    • 5 mil annealed copper tape with an overlap of 25%
  • Jacket:
    • Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)

EPR/PVC Power Cable with Copper Tape Shield (5kV and 8kV) Options:

  • PVC jacket colors other than black
  • Flame Retardant, Chlorinated Polyethylene (CPE) jacket
  • Low-Smoke, Zero-Halogen (LSZH) jacket
  • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610

EPR/PVC Power Cable with Copper Tape Shield (5kV and 8kV) Applications:

  • Superior performance in petrochemical plants, pulp and paper mills, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines, utility power generating stations and other industrial three-phrase applications
  • Suitable for use in wet or dry locations, when installed in accordance with NEC
  • For use in aerial, conduit, open tray and underground duct installations
  • For use in direct burial if installed ina system with a ground conductor that is in close proximity, and vonforms wiht NEC 250.4 (A) (5)

EPR/PVC Power Cable with Copper Tape Shield (5kV and 8kV) Features:

  • Rated at 105°C
  • Excellent heat and moisture resistance
  • Excellent flame resistance
  • Outstanding corona resistance
  • Flexibility for easy handling
  • High dielectric strength
  • Low moisture absorption
  • Electrical stability under stress
  • Low dielectric loss
  • Chemical resistant
  • Meets cold bend test at -35°C