Part Number AWG SizeConductor StrandingNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Nom. Dia. of Cond.
7050.6057-18 14 7/.0242 0.1700 24 .045 .07
7050.6056-18 12 7/.0305 0.1900 33 .045 .09
7050.6055-18 10 7/.0385 0.2100 48 .045 .12
7050.6054-18 8 7/.0486 0.2700 78 .060 .15
7050.6053-18 6 7/.0612 0.3100 114 .060 .18
7050.6052-18 4 7/.0772 0.3600 169 .060 .23
7050.6051-18 2 7/.0974 0.4200 254 .060 .29
7050.60755-18 1/0 19/.0740 0.5300 402 .080 .37
7050.6076-18 2/0 19/.0837 0.5800 500 .080 .41
7050.6077-18 4/0 19/.1055 0.6900 759 .080 .52
7050.608-18 250 37/.0822 0.7700 905 .095 .56
7050.6081-18 350 37/.0973 0.8700 1235 .095 .67
7050.60825-18 500 37/.1162 1.0000 1728 .095 .80
7050.6085-18 750 61/.1109 1.2200 2573 .110 .98
7050.60875-18 1000 61/.1280 1.3700 3402 .110 1.13

FR-EPR Low-Voltage Unshielded Power Cable
600 V, UL Type RHH/RHW-2/USE-2 LS

Product Approvals:

  • Industry Compliances:
    • National Electric Code (NEC)
    • ICEA S-95-658 / NEMA WC70
    • "FOR CT USE" on 1/0 AWC and larger in accordance with the NEC
    • UL 44 Type RHH/RHW-2
    • UL 854 Type USE-2
    • UL listed VW-1
  • Flame Test Compliances:
    • UL 1581 VW-1
    • For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT-4
  • Other Compliances:
    • EPA 40 CFR, Part 261 for leachable lead content per TCLP
    • OSHA acceptable

FR-EPR Power Cable - UL Type RHH/RHW-2/USE-2 LS Construction:

  • Conductor
    • 14 AWG thru 1000 kcmil stranded annealed bare copper compressed Class B stranding per ASTM B8
  • Insulation:
    • Flame Retardant Ethylene Propylene Rubber (EPR) colored for contrast with Black Low- Lead Hypalon® Chlorosulfonated Polyethylene (CSPE)/Elastomer blend

FR-EPR Power Cable - UL Type RHH/RHW-2/USE-2 LS Applications:

  • May be used in commercial, industrial, utility, free air, raceways, & direct burial applications

FR-EPR Power Cable - UL Type RHH/RHW-2/USE-2 LS Features:

  • Rated at 90°C wet or dry
  • Smaller cable diameter
  • Excellent electrical, thermal, and physical properties
  • Excellent resistance to moisture
  • Excellent resistance to crush, compression cuts, and heat deformation
  • Excellent flame resistance
  • Excellent low temperature cold bend characteristics
  • Resistant to most oils and chemicals
  • UV/sunlight-resistant
  • Meets cold bend test at -25°C