CSA TECK90 Three Conductor Unshielded Armored Power Cable (5kV)


Part Number AWG SizeNo. of Cond.Nom. O.D. of Cable (in)Approx LBS/MFTArmor (in)Ampacity @ 30°CGround AWG Size
8748.52755-18 1/0 3 1.87 2700 1.77 155 6
8748.776-18 2/0 3 1.96 3060 1.86 185 6
8748.52765-18 3/0 3 2.07 3550 1.97 210 4
8748.5277-18 4/0 3 2.18 4290 2.08 235 4
8748.528-18 250 3 2.35 4990 2.25 265 4
8748.5281-18 350 3 2.59 6340 2.46 325 3
8748.52825-18 500 3 2.85 8130 2.72 395 2

XLPE/PVC/GSIA/PVC Three Conductor Unshielded Armored Power Cable
5 kV, CSA TECK90

Product Approvals:

  • CSA FT1 and FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr
  • IEEE 1202 (70,000 BTU/hr) CSA FT4
  • ICEA T-30-520 (70,000 BTU/hr)
  • Hazardous Location Rating: HL
  • CSA Standard C22.2 No. 131 and No. 174
  • CSA Approval (file) numbers: LR1781
  • Meets EPA 40 CFR, part 261 for leachable lead content per TCLP method
  • OSHA acceptable

CSA TECK90 Three Conductor Unshielded Armored Power Cable (5kV) Construction:

  • Conductor: 1/0 AWG thru 500 kcmil bare copper compact strand
  • Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor
  • Insulation: Cross-Linked Polyethylene (XLPE) Type RW90; Color-Coded: Printed Numbers
  • Inner Jacket: Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)jacket with raised ribs- Black
  • Armor: Galvanized Steel Interlocked Armor (GSIA)
  • Jacket: ACID-FLAME CHECK flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC); Color coded: Orange

CSA TECK90 Three Conductor Unshielded Armored Power Cable (5kV) Applications:

  • For exposed and concealed wiring in dry, damp or wet locations
  • For use in ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations
  • For direct earth burial (with protection as required by inspections authority)
  • For wiring in all hazardous locations when used with certified HL cable glands
  • Cost-effective alternative to installation in conduit
  • Typical vertical installations include mine shafts, tall commercial buildings, inclined tunnels and vertical cable trays (Note that the overall jacket is required for all damp and wet locations and for all corrosive environments: CE Code part 1 Rules 12-708 and 22-200)

CSA TECK90 Three Conductor Unshielded Armored Power Cable (5kV) Features:

  • Rated at 90°C wet or dry
  • The jacket under the armor (inner jacket) is designed with longitudinal raised ribs. The armor is then applied and bites into these ribs to provide a solidly locked construction. This feature enables the cable to be self-supporting (core will not slip) during vertical installation when cable weight is supported by the copper conductors
  • Lighter than mine shaft cable with conventional steel wire armor (SWA)
  • More flexible that SWA cables resulting in easier handling during installation
  • Terminations and connections to electrical cabinets are similar to standard TECK90 cables
  • Meets cold bend and impact tests at -40°C

CSA TECK90 Three Conductor Unshielded Armored Power Cable (5kV) Options:

  • Three ground (bonding) conductors
  • Other constructions available upon request