CSA HVTECK Shielded Armored Power Cable (28kV)


Part Number AWG SizeNo. of Cond.Nom. O.D. of Cable (in)Approx LBS/MFTArmor (in)Ampacity @ 40°CGround AWG Size
8748.44505-18 1 3 3.10 3980 2.97 187 6
8748.44755-18 1/0 3 3.18 4360 3.05 215 6
8748.4476-18 2/0 3 3.36 4950 3.21 246 6
8748.44765-18 3/0 3 3.46 5490 3.31 283 4
8748.4477-18 4/0 3 3.58 6090 3.43 325 4
8748.448-18 250 3 3.70 6660 3.55 359 4
8748.4481-18 350 3 4.00 7960 3.85 438 3
TRXLPE/Tape Shield/PVC/AIA/PVC Three Conductor Shielded Armored Power Cable
28 kV, CSA HVTECK, 133% Ins. Level 345 Mils

Product Approvals:

  • CSA FT1 and FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr
  • IEEE 1202 (70,000 BTU/hr) CSA FT4
  • ICEA T-30-520 (70,000 BTU/hr)
  • ICEA T-29-520 (70,000 BTU/hr)
  • Hazardous Location Rating: HL
  • CSA Standard C68.3
  • CSA Standard C22.2 No. 174
  • CSA Approval (file) numbers: LR27161
  • Meets EPA 40 CFR, part 261 for leachable lead content per TCLP method
  • OSHA acceptable

CSA HVTECK Shielded Armored Power Cable (28kV) Construction:

  • Conductor: 1 AWG - 350 kcmil bare copper compact Class B strand
  • Ground (Bonding) Conductor: Uninsulated stranded bare copper conductor
  • Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
  • Insulation Shield: Semi-Conducting Thermosetting Layer, applied in triple extrusive process, plus helically applied gapped copper tape
    • Color-Coded: Black, Red or Blue colored tape placed longitudinally under copper tape shield
  • Inner Jacket: Flame retardant, moisture and sunlight resistant PVC - Black
  • Armor: Aluminum Interlocked Armor (AIA)
  • Overall Jacket: ACID-FLAME CHECK flame retardant, moisture and sunlight resistant PVC - Red
  • Strand Shield: Thermoset Semi-Conducting Strand Shield is extruded over conductor

CSA HVTECK Shielded Armored Power Cable (28kV) Options:

  • Galvanized Steel Interlocked Armor (GSIA)
  • Other constructions available upon request

CSA HVTECK Shielded Armored Power Cable (28kV) Applications:

  • Wiring in hazardous locations when used with certified HL cable glands
  • Exposed and concealed wiring in dry, damp or wet locations
  • Ventilated, non-ventilated and ladder-type cable trays in dry, damp or wet locations
  • Direct earth burial (with protection as required by inspections authority)

CSA HVTECK Shielded Armored Power Cable (28kV) Features:

  • Rated at 90°C wet or dry
  • Excellent crush, oil and chemical resistance
  • Long service life
  • Cost-effective alternative to installations in conduit
  • Meets cold bend and impact tests at -40°C