PVC/PVC Instrumentation Cable with Individual and Overall Shielded Triads

Part Number AWG SizeConductor StrandingApprox LBS/MFTNo. of TriadsNom. O.D. of Cable (in)Nom. Insul. Thick. (in)Jacket Thick
169935-18 20 7/.0121 59 2 .340 .012 .040
169940-18 20 7/.0121 97 4 .365 .012 .040
169945-18 20 7/.0121 187 8 .566 .012 .050
169950-18 20 7/.0121 287 12 .705 .012 .060
169955-18 20 7/.0121 365 16 .780 .012 .060
169960-18 20 7/.0121 440 20 .860 .012 .060
169965-18 20 7/.0121 541 24 .955 .012 .070
169970-18 20 7/.0121 767 36 1.115 .012 .070
162935-18 18 7/.0152 77 2 .321 .015 .040
169980-18 18 7/.0152 143 4 .444 .015 .050
174005-18 18 7/.0152 375 8 .786 .015 .060
380150-18 18 7/.0152 412 12 .840 .015 .060
169990-18 18 7/.0152 550 16 .960 .015 .070
169995-18 18 7/.0152 668 20 1.060 .015 .070
170000-18 18 7/.0152 785 24 1.145 .015 .070
170005-18 18 7/.0152 1151 36 1.365 .015 .080
170010-18 16 7/.0192 104 2 .367 .015 .040
170015-18 16 7/.0192 195 4 .502 .015 .050
170020-18 16 7/.0192 375 8 .786 .015 .060
170025-18 16 7/.0192 597 12 .970 .015 .070
170030-18 16 7/.0192 765 16 1.075 .015 .070
170035-18 16 7/.0192 933 20 1.195 .015 .070
170040-18 16 7/.0192 1125 24 1.310 .015 .080
170045-18 16 7/.0192 1620 36 1.540 .015 .080

PVC/PVC Instrumentation Cable with Individual and Overall Shielded Triads
UL Type PLTC, 300 V

PVC/ PVC Instrumentation Cable with Individual and Overall Shielded Triads Approvals:

  • PVC Instrumentation Cable Industry Compliances:
    • UL 13 Type PLTC/ITC
  • PVC Instrumentation Cable Flame Test Compliances:
    • IEEE 383 (70,000 BTU/hr)
    • UL Subject 13 (70,000 BTU/hr) for PLTC
    • UL Subject 2250 (70,000 BTU/hr) for ITC
  • Other PVC Instrumentation Cable Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

PVC/PVC Instrumentation Cable with Individual and Overall Shielded Triads Construction:

  • Conductor:
    • 20 AWG thru 16 AWG bare, annealed copper per ASTM B3
    • Class B stranding per ASTM B8
  • Insulation:
    • Polyvinylchloride (PVC)
    • Color-coded per ICEA Method 1:
      • Pairs: Black and White
      • Triads: Black, White and Red
  • Shield:
    • Individual and overall shielded triads
    • Individual triads are 100% shielded with aluminum/polyester in contact with stranded tinned copper drain wire
    • Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire
  • Jacket:
    • Sunlight-resistant Polyvinylchloride (PVC)
  • PVC Instrumentation Cable Options:
    • Tinned copper conductor
    • Class C Stranding
    • Other constructions for PVC Instrumentation Cable available upon request

PVC/PVC Instrumentation Cable with Individual and Overall Shielded Triads Applications:

  • PVC Instrumentation cable is acceptable for use in free air or raceways in accordance with NEC
  • Typical applications for PVC Instrumentation Cable include audio, intercom, control, energy management and alarm circuits.
  • In ducts, cable trays or conduit
  • In accordance with UL Subject 13 as Power-Limited Circuit Cable
  • In class 3 circuits in accordance with NEC
  • In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC)
  • Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC Article 501-4(b) for UL Type PLTC/ITC cables
  • Per NEC Article 727 for Type PLTC/ITC