Aluminum Jacketed Quadruplex Conductor Underground Power Cable

More Low Voltage Underground Power Cable Options

Part Number Phase Cond. - AWG SizePhase Cond.- Cond. Strand. Phase Cond. - Nom. Insul. Thick. (in)Phase Cond. - Jacket Thick. (in)Neutral Cond. - AWG Size Neutral Cond. - Cond. Strand.Neutral Cond. - Nom. Insul. Thick. (in)Neutral Cond - Jacket Thick. (in)Nom. EFF O.D. (in)Approx LBS/MFTAmpacity (Direct Burial)Ampacity (Duct in Air)
Tulsa/AR/EYS 4 7 0.030 0.030 4 7 0.030 0.030 0.86 273 125 70
Dyke/AR/EYS 2 7 0.030 0.030 4 7 0.030 0.030 0.97 363 160 90
Wittenberg/AR/EYS 2 7 0.030 0.030 2 7 0.030 0.030 1.00 393 160 90
Notre Dame/AR/EYS 1/0 19 0.040 0.040 2 7 0.030 0.030 1.22 561 205 125
Purdue/AR/EYS 1/0 19 0.040 0.040 1/0 19 0.040 0.040 1.29 617 205 125
Syracuse/AR/EYS 2/0 19 0.040 0.040 1 19 0.040 0.040 1.35 686 230 140
Lafayette/AR/EYS 2/0 19 0.040 0.040 2/0 19 0.040 0.040 1.40 744 230 140
Swarthmore/AR/EYS 3/0 19 0.040 0.040 1/0 19 0.040 0.040 1.47 830 265 160
Davidson/AR/EYS 3/0 19 0.040 0.040 3/0 19 0.040 0.040 1.52 902 265 160
Wake Forest/AR/EYS 4/0 19 0.040 0.040 2/0 19 0.040 0.040 1.58 1008 300 185
Earlham/AR/EYS 4/0 19 0.040 0.040 4/0 19 0.040 0.040 1.65 1096 300 185
Rust/AR/EYS 250 37 0.045 0.050 3/0 19 0.040 0.040 1.76 1218 325 210
Palomar/AR/EYS 250 37 0.045 0.050 250 37 0.045 0.050 1.84 1325 325 210
Slippery Rock/AR/EYS 350 37 0.045 0.050 4/0 19 0.040 0.040 1.98 1599 390 255
Niagara/AR/EYS 350 37 0.045 0.050 350 37 0.045 0.050 2.09 1768 390 255
Wofferd/AR/EYS 500 37 0.045 0.050 350 37 0.045 0.050 2.32 2251 475 310
Aluminum Jacketed Quadruplex Conductor Underground Power Cable
600V XLPE Insulation & HDXLPE Jacket

Aluminum Jacketed Quadruplex Conductor Underground Power Cable Construction:

  • Complete Cable:
    • Three phase conductors and one neutral conductor insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
    • Twisted cables form a quadruplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation & Jacket:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
    • The three phase conductors are black and the neutral conductor is black identified by three extruded yellow stripes.

Aluminum Jacketed Quadruplex Conductor Underground Power Cable Features and Benefits:

  • Insulation/Jacket system provide very high degree of protection against insulation damage from unclean backfill material and cuts and abrasions from installation
  • For NEC-complying applications, the maximum conductor operating temp is 90°C in wet or dry locations
  • Also suitable for non-code-complying installations with a temperature of 90°C in wet or dry locations in accordance with ICEA specifications

Aluminum Jacketed Quadruplex Conductor Underground Power Cable Applications:

  • Intended for use in underground systems operated at 600 volts or less.

Aluminum Jacketed Quadruplex Conductor Underground Power Cable Options:

  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • Sizes 250-500 kcmil available with UL-allowed thin wall (0.080") insulation
  • CDC Combined Duct & Cable
  • Reeless Package
  • PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
  • Type USE-2 per UL 44