TelcoFlex® III Central Office Power Cable

Part Number AWG SizeConductor StrandingNom. I.D. (in)Insulation Min. Avg. WallNom. O.D. (in)Max. Resistance @ 20°C OHMS/MFTApprox LBS/MFT
TELCO-14-L3 14 7/.0242 0.165 45 0.225 2.730 37.00
TELCO-12-L3 12 7/.0305 0.185 45 0.247 1.720 47.00
TELCO-10-L3 10 7/.0385 0.21 45 0.272 1.080 63.00
TELCO-8-L3 8 7/.0486 0.27 60 0.327 0.678 93.00
TELCO-6-L3 6 7/.0612 0.305 60 0.37 0.427 132.00
TELCO-4-L3 4 7/.0772 0.35 60 0.414 0.269 188.00
TELCO-2-L3 2 7/.0974 0.41 60 0.482 0.169 278.00
TELCO-1/0-L3 1/0 19/.0745 0.53 80 0.606 0.106 441.00
TELCO-2/0-L3 2/0 19/.0837 0.575 80 0.651 0.084 537.00
TELCO-4/0-L3 4/0 19/.1055 0.68 80 0.756 0.052 808.00
TELCO-350-L3 350 37/.0973 0.86 95 0.93 0.032 1290.00
TELCO-500-L3 500 37/.1162 0.99 95 1.066 0.022 1796.00
TELCO-750-L3 750 61/.1109 1.2 110 1.267 0.0148 2629.00
Power Cable
TelcoFlex III Central Office Cable

Class B Stranded with Braid
Low smoke, Non-halogenated Insulation With Cotton Braid, Lead-Free and Silicone-Free, UL Listed RHH/LS FT4 and VVW-1, 90°C Dry, 60°C Wet - 600 Volts, UL Listed "For CT Use" (Sizes 1/0 AWG and Larger), CSA AWM / B 105°C, 600V, FT4

Power Cable, TelcoFlex III Description:

  • These cables feature a single stranded tinned copper conductor, low smoke zero halogen TelcoHyde insulation, and an overall natural cotton braid covering. They are finished with a moisture resistant, flame retardant saturant which is applied to the braid. They are also available in a range of sizes from 14 AWG to 750 KCMIL.

Power Cable, TelcoFlex III Ratings and Approvals:

  • Temperature Rating: 90°C Dry and 60°C Wet
  • Voltage Rating: 600V
  • ASTM B-33
  • UL: RHH/LS, Listed for CT Use (Sizes 1/0 AWG and Larger)
  • CSA: AWM / B 105°C
  • FT4-ST1 Flame Test
  • VW-1
  • IEC 60674 and 60332
  • RoHS and Reach Compliant

Power Cable, TelcoFlex® III Construction:

  • Conductor: Stranded tinned copper conductor
  • Insulation: Limited smoke, non-halogen TelcoHyde 5221, which features a limiting oxygen rating of 35%
  • Separator: 1 mil clear mylar tape is applied over the insulation for sixes 6 AWG and larger
  • Covering: Overall natural cotton braid. A section of completed cable has a limiting oxygen index of 35%.
  • Finish: Moisture resistant and flame retardant saturant and color finisher are applied to the braid.