add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable (600 V)

Part Number AWG SizeNo. of Cond.Approx LBS/MFTGround AWG SizeNom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)Armor (in)
173315-18 8 3 420 10 0.045 0.050 0.84 0.74
173320-18 8 4 507 10 0.045 0.050 0.90 0.80
5649.015300-18 6 3 567 8 0.045 0.050 0.95 0.84
5649.020300-18 6 4 670 8 0.045 0.050 1.01 0.91
5649.015200-18 4 3 757 8 0.045 0.050 1.05 0.94
5649.020200-18 4 4 912 8 0.045 0.050 1.13 1.03
5649.015100-18 2 3 1075 6 0.045 0.050 1.18 1.07
5649.020100-18 2 4 1295 6 0.045 0.050 1.28 1.18
5649.015050-18 1 3 1269 6 0.045 0.050 1.29 1.19
5649.020050-18 1 4 1596 6 0.045 0.050 1.41 1.31
5649.017550-18 1/0 3 1528 6 0.045 0.050 1.38 1.27
5649.022550-18 1/0 4 1913 6 0.045 0.050 1.50 1.40
5649.017600-18 2/0 3 1860 6 0.045 0.050 1.48 1.37
5649.022600-18 2/0 4 2345 6 0.045 0.050 1.61 1.51
5649.017650-18 3/0 3 2259 4 0.045 0.050 1.59 1.48
5649.022650-18 3/0 4 2878 4 0.045 0.050 1.78 1.66
5649.017700-18 4/0 3 2840 4 0.045 0.050 1.79 1.66
5649.022700-18 4/0 4 3586 4 0.045 0.050 1.90 1.78
5649.018000-18 250 3 3295 4 0.065 0.060 1.94 1.81
5649.023000-18 250 4 4174 4 0.065 0.060 2.07 1.95
5649.018100-18 350 3 4400 3 0.065 0.060 2.16 2.03
5649.023100-18 350 4 5608 3 0.065 0.060 2.32 2.20
5649.018250-18 500 3 6126 2 0.065 0.075 2.46 2.30
5649.023250-18 500 4 7825 2 0.065 0.075 2.66 2.51
5649.018500-18 750 3 8806 1 0.080 0.075 2.89 2.74
5649.023500-18 750 4 11494 1 0.080 0.075 3.21 3.04
5649.018750-18 1000 3 11476 1/0 0.080 0.075 3.24 3.07
5649.023750-18 1000 4 14931 1/0 0.080 0.075 3.58 3.41

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable
UL Type MC, 600 V

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable Approvals:

  • National Electric Code (NEC)
  • UL 1569
  • UL 44
  • ICEA S-95-658/NEMA WC 70
  • UL Type MC- 600 volts
  • NEC Type XHHW-2 conductors
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • IEEE 1202 (70,000 BTU/hr)/CSA FT4
  • ICEA T-29-520 (210,000 BTU/hr)
  • Meets EPA 40 CFR part 261 leachable lead content per TCLP method
  • OSHA acceptable

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable Construction:

  • Conductor:
    • 8 AWG - 4/0 AWG bare copper compressed
    • Class B stranding per ASTM B3 and B8
  • Insulation:
    • Cross-Linked Polyethylene (XLPE)
    • Color-Coded: per ICEA Method 1: Table E-2
  • Ground:
    • Annealed bare copper Class B stranding per ASTM B8
  • Armor:
    • Aluminum Interlocked Armor (AIA)
  • Jacket:
    • Flame retardant, moisture and sunlight resistant PVC - black

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable Options:

  • Other constructions available

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable Applications:

  • Commercial, industrial and utility applications where maximum performance and easy installation is demanded and fire resistance is critical
  • Permitted for Class I Division 2, Class II Division 2, and Class III Division 1 and 2 per NEC Article 334
  • Exposed or concealed work, wet or dry locations, indoors or outdoors and cable trays

XLPE/AIA/PVC 3 and 4 Conductor Armored Power Cable Features:

  • Rated at 90°C wet or dry
  • Provides excellent oil, sunlight, chemical, and crush resistance
  • Long service life
  • Cost-effective alternative to installations in conduit
  • Meets cold bend test at -25°C