This symmetrical-lean VFD tray cable is designed for use with automated servo systems. It is a machine-tool cable to be used in accordance with the National Electrical Code and the NFPA Electrical Standard for Industrial Machinery (NFPA 79). It may be used without conduits and is suitable for tray cable applications. It may be used to connect alternating current variable frequency drives to alternating current variable frequency motors. It may be installed in wet or dry locations, indoor and outdoor applications, and even in direct burial applications.

9 items

  • 43208015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 16
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43207015
    $0.00 / 100 FT
    • Approx LBS/MFT: 0.00
    • AWG Size: 14
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43206015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 12
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43205015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 10
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43204015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 8
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43203015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 6
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43202015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 4
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 43201015-54
    $0.00 /
    • Approx LBS/MFT: 0.00
    • AWG Size: 2
    • Cond. Material: Tinned Copper
    Order
    Add to List

Symmetrical Lean VFD Tray Cable Specifications

Symmetrical Lean VFD Construction:

  • Conductor: Tinned Copper, Stranded
  • Insulation: PVC/Nylon
  • Color Code: Black Conductors with Consecutive White Numbers
  • Shield: Double Shield, Aluminum Foil and Tinned Copper Braiding
  • Stranding: In Layers with 3 Tinned Ground Wires
  • Jacket: Sunlight and Oil Resistant PVC
  • Jacket Color: Black

Symmetrical Lean VFD Technical Data:

  • Voltage:
    • (UL)/c(UL): 600V
    • UL-AWM/CSA-AWM: 1000V
    • (UL)WTTC: 1000V
  • Testing Voltage:
    • Conductor/Conductor: 7500V
    • Conductor/Screen: 3000V
  • Minimum Bending Radius: 12 x O.D.
  • Temperature:
    • UL-AWM: up to 105°C
    • (UL)/c(UL)/CSA-AWM: up to 90°C
    • Static: -25°C

Symmetrical Lean VFD Approvals:

  • UL:
    • Type WTTC: UL Subject 2277
    • Type TC: UL Standard 1277
  • NFPA 79 for Industrial Machinery
  • Flame Tests: (UL)/c(UL) FT4, c(UL)/CSA-AWM FT1, FT2