Our Jacketed Quadruplex Conductor Underground Power Cable is suitable for use in underground systems operated at 600 volts or less. This cable's XLPE insulation and jacketing provide a high degree of protection against unclean backfill material, cuts, and abrasions. This cable is suitable for non-code-complying locations in accordance with ICEA specifications. It has a maximum temperature of +90°C in wet and dry locations.

16 items

  • DAVIDSON
    $0.00 /
    • Ampacity (Direct Burial): 265
    • Ampacity (Duct in Air): 160
    • Approx LBS/MFT: 902
    Order
    Add to List
  • $0.00 / 100 FT
    • Ampacity (Direct Burial): 160
    • Ampacity (Duct in Air): 90
    • Approx LBS/MFT: 363
    Order
    Add to List
  • EARLHAM
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 300
    • Ampacity (Duct in Air): 185
    • Approx LBS/MFT: 1096
    Order
    Add to List
  • Lafayette/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 230
    • Ampacity (Duct in Air): 140
    • Approx LBS/MFT: 744
    Order
    Add to List
  • Niagara/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 390
    • Ampacity (Duct in Air): 255
    • Approx LBS/MFT: 1768
    Order
    Add to List
  • Notre Dame/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 205
    • Ampacity (Duct in Air): 125
    • Approx LBS/MFT: 561
    Order
    Add to List
  • Palomar/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 325
    • Ampacity (Duct in Air): 210
    • Approx LBS/MFT: 1325
    Order
    Add to List
  • PURDUE
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 205
    • Ampacity (Duct in Air): 125
    • Approx LBS/MFT: 617
    Order
    Add to List

Aluminum Jacketed Quadruplex Conductor Underground Power Cable

Jacketed Quadruplex Power Cable Construction:

  • Complete Cable:
    • Three phase conductors and one neutral conductor insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
    • Twisted cables form a quadruplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation & Jacket:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
    • The three phase conductors are black and the neutral conductor is black identified by three extruded yellow stripes.

Jacketed Quadruplex Power Cable Ratings and Approvals:

  • Max. Temperature: 90°C wet or dry
  • Voltage Rating: 600V
  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • Sizes 250-500 kcmil available with UL-allowed thin wall (0.080") insulation
  • CDC Combined Duct & Cable
  • Reeless Package
  • PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
  • Type USE-2 per UL 44