Our Jacketed Triplex Conductor Underground Power Cable is suitable for use in underground systems operated at 600 volts or less. This cable's XLPE insulation and jacketing provide a high degree of protection against unclean backfill material, cuts, and abrasions. This cable is suitable for non-code-complying locations in accordance with ICEA specifications. It has a maximum temperature of +90°C in wet and dry locations.

17 items

  • Bergen/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 240
    • Ampacity (Duct in Air): 150
    • Approx LBS/MFT: 462
    Order
    Add to List
  • Brenau/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 240
    • Ampacity (Duct in Air): 150
    • Approx LBS/MFT: 406
    Order
    Add to List
  • Converse/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 270
    • Ampacity (Duct in Air): 170
    • Approx LBS/MFT: 499
    Order
    Add to List
  • Grossmont/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 210
    • Ampacity (Duct in Air): 130
    • Approx LBS/MFT: 385
    Order
    Add to List
  • Hollins/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 310
    • Ampacity (Duct in Air): 195
    • Approx LBS/MFT: 604
    Order
    Add to List
  • Hunter/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 270
    • Ampacity (Duct in Air): 170
    • Approx LBS/MFT: 557
    Order
    Add to List
  • Monmouth/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 350
    • Ampacity (Duct in Air): 225
    • Approx LBS/MFT: 821
    Order
    Add to List
  • Newark/AR/EYS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 460
    • Ampacity (Duct in Air): 310
    • Approx LBS/MFT: 1324
    Order
    Add to List

Aluminum Jacketed Triplex Conductor Underground Power Cable

Jacketed Triplex Power Cable Construction:

  • Complete Cable:
    • Two phase conductors and one neutral conductor insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
    • Twisted cables form triplex assembly
    • Manufactured in accordance with ANSI/ICEA Standard S-81-570
    • When specified, produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting ASTM B231 or 786
  • Insulation & Jacket:
    • Insulation is XLPE
    • Jacket is HDXLPE and meets ASTM D1248, Type III
    • Phase conductors are black and neutral conductor is black with three extruded yellow stripes.

Jacketed Triplex Power Cable Ratings and Approvals:

  • Max. Temperature: 90°C wet or dry
  • Voltage Rating: 600V
  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • Sizes 250-500 kcmil available with UL-allowed thin wall (0.080") insulation
  • CDC Combined Duct & Cable
  • Reeless Package
  • PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
  • Type USE-2 per UL 44