Lapp Olflex CONTROL TM CY Cable


Shielded Extremely Oil-Resistant Flexible Control Cable
UL MTW & UL/CSA TC
Olflex CONTROL TM CY Cable Construction:
  • Conductors: Finely stranded bare copper (Class 5 fine wire)
  • Insulation: Specially blended PVC/Nylon
  • Shielding: Foil tape and tinned copper braid (85% coverage)
  • Color Code: Black with white numbers, plus green/yellow ground
  • Jacket: Specially formulated gray PVC
Olflex CONTROL TM CY Cable Technical Data:
  • Temperature Range:
    • UL/CSA TC: -25°C to +90°C
    • For stationary use: -40 to +105°C
    • For flexible use: -25°C to +90°C
  • Nominal Voltage:
    • UL/CSA TC: 600V
    • UL WTTC: 1000V
  • Test Voltage: 2000V
  • Minimum Bend Radius- Shielded: 6 x cable diameter
Olflex CONTROL TM CY Cable Approvals:
  • UL:
    • TC-ER per UL 1277
    • MTW per UL 1063
    • WTTC per UL 2277
    • Bus Drop Cable (14 AWG & larger; 3c & 4c only)
    • AWM 2587 & 21098 (Oil)
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight resistant
    • Direct burial
    • NFPA 79 2012
  • NEC: Class 1, Division 2 per NEC Article 501
  • Canada:
    • c(UL) CIC/TC FT4
    • CSA AWM I/II A/B FT4
  • Additional:
    • Torsion rated for wind market (± 90°/m) & (± 150°/m)
    • Passes impact and crush test per UL 1277 (except 20 AWG)
    • CE & RoHS
Olflex CONTROL TM CY Cable Applications:
  • Machine tool machinery
  • Food and beverage
  • Processing equipment
  • Machine wiring for conformance to NFPA 79 2012
Olflex CONTROL TM CY Cable Characteristics and Benefits:
  • Industrial grade PVC jacket (Oil Res I/II)
  • Meets NFPA 79 2012 standards for wiring machinery (UL MTW)
  • Number-coded for easy connection
  • UL TC-ER approval - can be installed off the machine and into an overhead tray without conduit
  • Shield for added protection against noise and interference
  • Flexible copper stranding and pressure-extruded jacket, improved shielding effectiveness


Need an unshielded version of this cable? See Olflex CONTROL TM Cable specs.
Part Number AWG SizeNo. of Cond.Nom. O.D. (in)Copper LBS/MFTApprox LBS/MFT
281803CY 18 3 0.3160 37 79
281804CY 18 4 0.3150 26 64
281805CY 18 5 0.3400 33 75
281807CY 18 7 0.3920 69 130
281812CY 18 12 0.5020 109 223
281819CY 18 19 0.6100 172 295
281825CY 18 25 0.6870 222 386
281603CY 16 3 0.3440 44 97
281604CY 16 4 0.3700 60 117
281605CY 16 5 0.4000 72 128
281607CY 16 7 0.4370 94 165
281612CY 16 12 0.5880 151 287
281618CY 16 18 0.6750 227 326
281625CY 16 25 0.7640 305 476
281403CY 14 3 0.3810 71 121
281404CY 14 4 0.4110 91 150
281405CY 14 5 0.4520 108 181
281407CY 14 7 0.4880 143 220
281412CY 14 12 0.6590 246 399
281419CY 14 19 0.7600 369 527
281425CY 14 25 0.9030 474 705
281203CY 12 3 0.4480 104 161
281204CY 12 4 0.4850 133 212
281205CY 12 5 0.5600 163 260
281207CY 12 7 0.6040 217 452
281003CY 10 3 0.5550 150 271
281004CY 10 4 0.6010 191 370
281005CY 10 5 0.6540 245 412
281007CY 10 7 0.7090 330 575