The Lapp Control TM CY Cable is suitable for use in machine tools, food and beverage equipment, and processing equipment. This cable features flexible copper stranding, a pressure-extruded jacket, and number-coded conductors for easy connection. It also features a foil tape and braided tinned copper shield that provides 85 percent coverage. This cable is TC-ER approved, meaning it may be installed off the machine and into an overhead tray without conduit.

29 items

281803cy
Approx LBS/MFT79.00
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT37
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Requires Quote per FT 
281804cy
Approx LBS/MFT64.00
AWG Size18
Cond. MaterialBare Copper
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.3150
Requires Quote per FT 
281805cy
Approx LBS/MFT75
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT33
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Requires Quote 
281807cy
Approx LBS/MFT130.00
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT69
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.7
Requires Quote per FT 
281812cy
Approx LBS/MFT223
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT109
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.12
Requires Quote 
281819cy
Approx LBS/MFT295
AWG Size18
Cond. MaterialBare Copper
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.19
Nom. O.D. (in)0.6100
Requires Quote 
281825cy
Approx LBS/MFT386
AWG Size18
Cond. MaterialBare Copper
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.25
Nom. O.D. (in)0.6870
Requires Quote 
281603cy
Approx LBS/MFT97.00
AWG Size16
Cond. MaterialBare Copper
Copper LBS/MFT44
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Requires Quote per FT 

Lapp Control TM CY Cable Specifications

Control TM CY Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 fine wire)
  • Insulation: Specially blended PVC/Nylon
  • Shielding: Foil tape and tinned copper braid (85% coverage)
  • Color Code: Black with white numbers, plus green/yellow ground
  • Jacket: Specially formulated gray PVC

Control TM CY Cable Ratings and Approvals:

  • Temperature Range:
    • UL/CSA TC: -25°C to +90°C
    • For stationary use: -40 to +105°C
    • For flexible use: -25°C to +90°C
  • Nominal Voltage:
    • UL/CSA TC: 600V
    • UL WTTC: 1000V
  • Test Voltage: 2000V
  • Minimum Bend Radius- Shielded: 6 x cable diameter
  • UL:
    • TC-ER per UL 1277
    • MTW per UL 1063
    • WTTC per UL 2277
    • Bus Drop Cable (14 AWG & larger; 3c & 4c only)
    • AWM 2587 & 21098 (Oil)
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight resistant
    • Direct burial
    • NFPA 79 2012
  • NEC: Class 1, Division 2 per NEC Article 501
  • Canada:
    • c(UL) CIC/TC FT4
    • CSA AWM I/II A/B FT4
  • Additional:
    • Torsion rated for wind market (± 90°/m) & (± 150°/m)
    • Passes impact and crush test per UL 1277 (except 20 AWG)