8866 - Instrumentation Cable (18 AWG)
Belden 8866 is a instrumentation cable designed for industrial instrumentation and control applications.
This cable features 18 AWG, 16-strand tinned copper conductors. the cable uses Korona-Guard Conductive Polyethylene (PE) insulation and a Polyvinylchloride (PVC) jacket, with nominal outside diameter of 0.208 inches. The cable operates up to 80C. Approximate weight is 20 lbs/MFT.
To explore additional configurations and related part numbers, browse the full Belden cable product line.
Contact Allied Wire & Cable for pricing, availability, and technical support.
Frequently Asked Questions
What is the conductor size of Belden 8866?
Belden 8866 features 18 AWG conductors.
What is the outside diameter of Belden 8866?
Belden 8866 has a nominal outside diameter of 0.208 inches.
What is the temperature rating for Belden 8866?
Belden 8866 is rated for operation up to 80C.
8866
Part Number
8866
Attributes
20
18
Tinned Copper
16/30
Korona-Guard Conductive Polyethylene (PE)
Polyvinylchloride (PVC)
0.015
80C
16
0.057
0.2080
30