Aluminum Triplex Conductor Underground Power Cable

Part Number Phase Cond.- Cond. Strand. Phase Cond. - AWG SizePhase Cond. - Nom. Insul. Thick. (in)Neutral Cond. - AWG Size Neutral Cond. - Cond. Strand.Neutral Cond. - Nom. Insul. Thick. (in)Nom. EFF O.D. (in)Approx LBS/MFTAmpacity (Direct Burial)Ampacity (Duct in Air)
Erskine 7 6 0.060 6 7 0.060 0.65 139 110 65
Vassar 7 4 0.060 4 7 0.060 0.75 197 145 85
Stephens 7 2 0.060 4 7 0.060 0.84 265 185 110
Ramapo 7 2 0.060 2 7 0.060 0.88 286 185 140
Brenau 19 1/0 0.080 2 7 0.060 1.06 395 240 150
Bergen 19 1/0 0.080 1/0 19 0.080 1.14 451 240 150
Converse 19 2/0 0.080 1 19 0.080 1.18 487 270 170
Hunter 19 2/0 0.080 2/0 19 0.080 1.23 544 270 170
Hollins 19 3/0 0.080 1/0 19 0.080 1.26 590 310 195
Rockland 19 3/0 0.080 3/0 19 0.080 1.34 661 310 195
Sweetbriar 19 4/0 0.080 2/0 19 0.080 1.38 718 350 225
Monmouth 19 4/0 0.080 4/0 19 0.080 1.46 805 350 225
Pratt 37 250 0.095 3/0 19 0.080 1.53 869 380 250
Wesleyan 37 350 0.095 4/0 19 0.080 1.72 1136 460 310
Rider 37 500 0.095 350 37 0.095 2.03 1621 560 380
Aluminum Triplex Conductor Underground Power Cable
600V XLPE Insulation

Aluminum Triplex Conductor Underground Power Cable Construction:

  • Complete Cable:
    • 2 phase conductors and 1 neutral conductor insulated with Extruded Cross-Linked Polyethylene (XLPE)
    • Twisted cables form Triplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-105-692
    • When specified, cable produced in accordance with UL 854 and listed as Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting requirements of ASTM B231 or B786
  • Insulation:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • 2 phase conductors are black; neutral conductor is black identified by 3 extruded yellow stripes.

Aluminum Triplex Conductor Underground Power Cable Features and Benefits:

  • Suitable for direct burial or installations in ducts
  • Resistant to abrasion, sunlight, and impact
  • For NEC-complying applications, maximum conductor operating temp is 90°C in wet or dry locations
  • Also suitable for non-code-complying temperature of 90°C in wet or dry locations in accordance with ICEA specifications

Aluminum Triplex Conductor Underground Power Cable Applications:

  • Underground systems operated at 600 volts or less.

Aluminum Triplex Conductor Underground Power Cable Options:

  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • Sizes 250 - 500 kcmil available with UL-allowed thin wall (0.080") insulation