Computer Cable

Computer Cables are part of Allied Wire and Cable’s extensive stock of Data Communications Cables. They are available in a variety of constructions to meet the needs of any application. Multi-conductor foil shield models, multi-paired foil/braid shield models, and low-capacitance individually foil shielded models are just a few of the many options Allied supplies. For full product specifications, click the links listed below.

In today’s electronic world, data cables are vital and are constantly being updated to follow the newest advances in technology. Computer applications require extremely flexible cables with very small cross sections and the best shielding available. For most computer cables and their applications, noise rejection is critical. Allied offers cables with a wide range of shielding options to account for these needs. From foil and braid shielded cable to individually foil shielded computer cable, Allied supplies the shielded cable you need for clean data transmission.

Common applications for computer cables include Ethernet, voice, and networking systems, as well as control circuits, computer interconnections, data transmissions, intercom systems, and industrial equipment controls. Because these cables are generally very flexible, they may be used in fixed installations, free moving applications, and wet or dry conditions.

Computer Cables are designed for indoor use only.

LSC5FS-4

LSC5FS-4 Construction:

  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Tape: Foam Polypropylene (PE) 25% Overlap
  • Drain: 24 AWG Stranded Tinned Copper 
  • Tape: Flame Retardant Tape 25% Overlap
  • Tape: Fiberglass Tape 25% Overlap
  • Tape: Marker Tape 

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5OS-4

LSC5OS-4 Construction:

  • Category 5 Defense-Link™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Tape: Polypropylene (PE) 25% Overlap
  • Shield: Aluminum/Polyester
  • Braid: 36 AWG Tinned Copper

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5OS-4

LSC5OSW-4 Construction:

  • Category 5e Shielded Defense-Link™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Gel: Cable Filled with Water Blocking
  • Both Tapes: Water Blocking Tape
  • Braid: 36 AWG Tinned Copper

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5POS-4 Compose Construction:

LSC5POS-4

  • Category 5e Shielded Defense-Link ™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to Varying Lays
  • Cable Assembly: 4 Pairs Cabled With Separator
  • 36 AWG Tinned Copper Braid
  • Tape: Polypropylene 25% Overlap

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2017-354

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown