Our Triplex Conductor Underground power cable is suitable for direct burial applications, installations in ducts, and underground systems that operate at 600 volts or less. It is also suitable for non-code-complying temperature of 90°C in wet or dry locations in accordance with ICEA specifications. This cable is resistant to abrasion, sunlight, and impact. It is also offered with varying constructions.

15 items

  • BERGEN
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 240
    • Ampacity (Duct in Air): 150
    • Approx LBS/MFT: 451
    Order
    Add to List
  • BRENAU
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 240
    • Ampacity (Duct in Air): 150
    • Approx LBS/MFT: 395
    Order
    Add to List
  • Converse
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 270
    • Ampacity (Duct in Air): 170
    • Approx LBS/MFT: 487
    Order
    Add to List
  • ERSKINE
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 110
    • Ampacity (Duct in Air): 65
    • Approx LBS/MFT: 139
    Order
    Add to List
  • HOLLINS
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 310
    • Ampacity (Duct in Air): 195
    • Approx LBS/MFT: 590
    Order
    Add to List
  • HUNTER
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 270
    • Ampacity (Duct in Air): 170
    • Approx LBS/MFT: 544
    Order
    Add to List
  • MONMOUTH
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 350
    • Ampacity (Duct in Air): 225
    • Approx LBS/MFT: 805
    Order
    Add to List
  • PRATT
    $0.00 / 100 FT
    • Ampacity (Direct Burial): 380
    • Ampacity (Duct in Air): 250
    • Approx LBS/MFT: 869
    Order
    Add to List

Aluminum Triplex Conductor Underground Power Cable Specifications

Triplex Underground Power Cable Construction:

  • Complete Cable:
    • 2 phase conductors and 1 neutral conductor insulated with Extruded Cross-Linked Polyethylene (XLPE)
    • Twisted cables form Triplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-105-692
    • When specified, cable produced in accordance with UL 854 and listed as Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting requirements of ASTM B231 or B786
  • Insulation:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • 2 phase conductors are black; neutral conductor is black identified by 3 extruded yellow stripes.

Triplex Underground Power Cable Ratings and Approvals:

  • Max. Temperature: 90°C wet or dry
  • Voltage Rating: 600V
  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • Sizes 250 - 500 kcmil available with UL-allowed thin wall (0.080") insulation
  • CDC Combined Duct & Cable
  • Reeless Package
  • Alloy 8000 Aluminum Conductor
  • Type RHH/RHW-2 rating to UL 44
  • Type USE-2 per UL 44