Home
loading content

Special Audio & Communication

10 items

2662
Composite Construction(2) 20 AWG 7/28 Shielded Conductors and (2) 20 AWG 7/28 Unshielded Conductors
Cond. MaterialTinned Copper
Drain WireStranded Tinned Copper Drain Wire
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.032
Max. Temp80C
Min. Temp-20C
Requires Quote per FT 
2666
Composite Construction(2) 20 AWG 10/30 Shielded Conductors and (1) 20 AWG 7/28 Unshielded Conductor
Cond. MaterialTinned Copper
Drain WireStranded Tinned Copper Drain Wire
Insul. MaterialPolyethylene (PE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.028
Max. Temp60C
Min. Temp-20C
Requires Quote per FT 
2676
Composite Construction(1) 22 AWG 7/30 Shielded Pair and (1) 22 AWG 7/30 Unshielded Pair
Cond. MaterialTinned Copper
Insul. MaterialPolyethylene (PE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.030
Max. Temp60C
Min. Temp-20C
No. of Pairs2
Requires Quote per FT 
2680
Composite Construction(2) 22 AWG 7/30 Shielded Conductors and (2) 22 AWG 7/30 Unshielded Conductors
Cond. MaterialTinned Copper
Drain WireStranded Tinned Copper Drain Wire
Insul. MaterialPolypropylene (PP)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.017
Max. Temp60C
Min. Temp-20C
Requires Quote per FT 
2686
Composite Construction(2) 20 AWG 7/28 Shielded Conductors and (2) 18 AWG 16/30 Unshielded Conductors
Cond. MaterialTinned Copper
Drain WireStranded Tinned Copper Drain Wire
Insul. MaterialPolypropylene (PP)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.032
Max. Temp60C
Min. Temp-20C
Starting at 0.57 per FT In Stock
90478
Composite Construction(2 Quads) 24 AWG 7/32 Shielded PE Conductors and (2) 22 AWG 7/30 Unshielded PVC Conductors
Cond. MaterialTinned Copper
Drain Wire24 AWG Stranded Tinned Copper Drain Wire
Insul. MaterialPolyvinylchloride (PVC)/Polyethylene (PE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.030
Max. Temp80C
Min. Temp-20C
Requires Quote per FT 
992006
Composite Construction(3) 20 AWG 7/28 Unshielded Conductors and (3) 16 AWG 19/28 Unshielded Conductors
Cond. MaterialTinned Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.032
Max. Temp90C
No. of Cond.6
Nom. Cap. (C-C)20, 30
Requires Quote per FT 
992204b
Composite Construction(1) 22 AWG 7/30 Shielded Pair and (1) 22 AWG 7/30 Unshielded Pair
Cond. MaterialTinned Copper
Drain Wire24 AWG Stranded Tinned Copper Drain Wire
Insul. MaterialPolypropylene (PP)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.030
Max. Temp80C
Min. Temp-20C
Requires Quote per FT