Home
loading content

CM, CMR, and CMP Rated

11 items

Approx LBS/MFT78
AWG Size26
Cond. MaterialBare Copper
Conductor Stranding7/34
Dielectric (in)0.09
Dielectric MaterialFoam High-Density Polyethylene (HDPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote per FT 
Approx LBS/MFT105
AWG Size26
Cond. MaterialBare Copper
Conductor Stranding7/34
Dielectric (in)0.09
Dielectric MaterialFoam High-Density Polyethylene (HDPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote per FT 
Approx LBS/MFT119
AWG Size26
Cond. MaterialBare Copper
Conductor Stranding7/34
Dielectric (in)0.09
Dielectric MaterialFoam High-Density Polyethylene (HDPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote per FT 
Approx LBS/MFT41
AWG Size25
Cond. MaterialTinned Copper
Conductor Strandingsolid
Dielectric (in)0.074
Dielectric MaterialFoam Perfluoroalkoxy (FPFA)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote 
Approx LBS/MFT48
AWG Size25
Cond. MaterialTinned Copper
Conductor Strandingsolid
Dielectric (in)0.074
Dielectric MaterialFoam Perfluoroalkoxy (FPFA)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote per FT 
Approx LBS/MFT52
AWG Size25
Cond. MaterialTinned Copper
Conductor Strandingsolid
Dielectric (in)0.074
Dielectric MaterialFoam Perfluoroalkoxy (FPFA)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote 
Approx LBS/MFT60
AWG Size25
Cond. MaterialTinned Copper
Conductor Strandingsolid
Dielectric (in)0.074
Dielectric MaterialFoam Perfluoroalkoxy (FPFA)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote 
Approx LBS/MFT68
AWG Size25
Cond. MaterialTinned Copper
Conductor Strandingsolid
Dielectric (in)0.074
Dielectric MaterialFoam Perfluoroalkoxy (FPFA)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp60C
Requires Quote per FT 

Belden CM, CMR, and CMP Rated RGB Cable Specifications

RGB Cable Construction:

  • Type CM Cable:
    • Conductor: 26 AWG Stranded Bare Copper
    • Insulation: Foam High-Density Polyethylene (HDPE)
    • Jacket: Inner PVC Jackets, Overall Black PVC Jacket
    • Shielding: Duofoil (100% Coverage) and Tinned Copper Braid (93% Coverage), Overall Polyester Tape
  • Type CMR Cable:
    • Conductor: 25 AWG Solid Tinned Copper
    • Insulation: Foam Perfluoroalkoxy (FPFA)
    • Jacket: Inner PVC Jacket, Overall Black PVC Jacket
    • Shielding: Duobond (100% Coverage) and Tinned Copper Interlocked Serve Shield (95% Coverage)
  • Type CMP Cable:
    • Conductor: 25 AWG Solid Tinned Copper
    • Insulation: Foam Perfluoroalkoxy (FPFA)
    • Jacket: Inner Fluorocopolymer Jacket, Overall Grey PVC Jacket
    • Shielding: Duobond (100% Coverage) and Tinned Copper Interlocked Serve Shield (95% Coverage)

RGB Cable Ratings and Approvals:

  • Type CM Cable (Non-Plenum Cable):
    • NEC Type CM
    • CEC Type CM
    • UL AWM Style 1354 and 2668: 30V, 60°C
  • Type CMR Cable (Riser-Rated):
    • NEC Type CMR
    • CEC Type CMG
    • Voltage Rating: 300V RMS
    • Maximum Temperature Rating: 60°C
  • Type CMP Cable (Plenum-Rated):
    • NEC Type CMP
    • CEC Type CMP
    • Voltage Rating: 300V RMS
    • Temperature Rating: 60°C